Self-Reinforced Composite Materials: Frictional Analysis and Its Implications for Prosthetic Socket Design

Friction and wear characteristics play a critical role in the functionality and durability of prosthetic sockets, which are essential components in lower-limb prostheses. Traditionally, these sockets are manufactured from bulk polymers or composite materials reinforced with advanced carbon, glass, and Kevlar fibres. However, issues of accessibility, affordability, and sustainability remain, particularly in less-resourced regions. This study investigates the potential of self-reinforced polymer composites (SRPCs), including poly-lactic acid (PLA), polyethylene terephthalate (PET), glass fibre (GF), and carbon fibre (CF), as sustainable alternatives for socket manufacturing. The tribological behaviour of these self-reinforced polymers (SrPs) was evaluated through experimental friction tests, comparing their performance to commonly used materials like high-density polyethylene (HDPE) and polypropylene (PP). Under varying loads and rotational speeds, HDPE and PP exhibited lower coefficients of friction (COF) compared to SrPLA, SrPET, SrGF, and SrCF. SrPLA recorded the highest average COF of 0.45 at 5 N and 240 rpm, while SrPET demonstrated the lowest COF of 0.15 under the same conditions. Microscopic analysis revealed significant variations in wear depth, with SrPLA showing the most profound wear, followed by SrCF, SrGF, and SrPET. In all cases, debris from the reinforcement adhered to the steel ball surface, influencing the COF. While these findings are based on friction tests against steel, they provide valuable insights into the durability and wear resistance of SRPCs, a crucial consideration for socket applications. This study highlights the importance of tribological analysis for optimising prosthetic socket design, contributing to enhanced functionality and comfort for amputees. Further research, including friction testing with skin-contact scenarios, is necessary to fully understand the implications of these materials in real-world prosthetic applications.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-11-18
DOI
https://doi.org/10.3390/ma17225629
Citations
7
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
4.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Reinforced Composite Materials: Frictional Analysis and Its Implications for Prosthetic Socket Design

Yasasween Hewavidana, Emrah Demirci, Y. Sun, Farukh Farukh et al.
7 citations
Materials
Orthopaedic implants and arthroplasty
4.01
article

Self-Reinforced Composite Materials: Frictional Analysis and Its Implications for Prosthetic Socket Design

Yasasween Hewavidana, Emrah Demirci, Y. Sun, Farukh Farukh, Yogeshvaran R. Nagarajan, Karthikeyan Kandan
article en
7 citations

Abstract

Friction and wear characteristics play a critical role in the functionality and durability of prosthetic sockets, which are essential components in lower-limb prostheses. Traditionally, these sockets are manufactured from bulk polymers or composite materials reinforced with advanced carbon, glass, and Kevlar fibres. However, issues of accessibility, affordability, and sustainability remain, particularly in less-resourced regions. This study investigates the potential of self-reinforced polymer composites (SRPCs), including poly-lactic acid (PLA), polyethylene terephthalate (PET), glass fibre (GF), and carbon fibre (CF), as sustainable alternatives for socket manufacturing. The tribological behaviour of these self-reinforced polymers (SrPs) was evaluated through experimental friction tests, comparing their performance to commonly used materials like high-density polyethylene (HDPE) and polypropylene (PP). Under varying loads and rotational speeds, HDPE and PP exhibited lower coefficients of friction (COF) compared to SrPLA, SrPET, SrGF, and SrCF. SrPLA recorded the highest average COF of 0.45 at 5 N and 240 rpm, while SrPET demonstrated the lowest COF of 0.15 under the same conditions. Microscopic analysis revealed significant variations in wear depth, with SrPLA showing the most profound wear, followed by SrCF, SrGF, and SrPET. In all cases, debris from the reinforcement adhered to the steel ball surface, influencing the COF. While these findings are based on friction tests against steel, they provide valuable insights into the durability and wear resistance of SRPCs, a crucial consideration for socket applications. This study highlights the importance of tribological analysis for optimising prosthetic socket design, contributing to enhanced functionality and comfort for amputees. Further research, including friction testing with skin-contact scenarios, is necessary to fully understand the implications of these materials in real-world prosthetic applications.

MaterialsVol. 17(22)
University of Nottingham (GB), Loughborough University (GB), State University of Padang (ID), De Montfort University (GB)
Royal Academy of Engineering, Engineering and Physical Sciences Research Council
Responsible consumption and production
Openalex Percentile: Top 6%
Orthopaedic implants and arthroplasty
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.