Quantitative Investigation of Layer-by-Layer Deposition and Dissolution Kinetics by New Label-Free Analytics Based on Low-Q-Whispering Gallery Modes

A new instrument for label-free measurements based on optical Low-Q Whispering Gallery Modes (WGMs) for various applications is used for a detailed study of the deposition and release of Layer-by-Layer polymer coatings. The two selected coating pairs interact either via hydrogen bonding or electrostatic interactions. Their assembly was followed by common Quartz Crystal Microbalance (QCM) technology and the Low-Q WGMs. In contrast to planar QCM sensor chips of 1 cm, the WGM sensors are fluorescent spherical beads with diameters of 10.2 µm, enabling the detection of analyte quantities in the femtogram range in tiny volumes. The beads, with a very smooth surface and high refractive index, act as resonators for circular light waves that can revolve up to 10,000 times within the bead. The WGM frequencies are highly sensitive to changes in particle diameter and the refractive index of the surrounding medium. Hence, the adsorption of molecules shifts the resonance frequency, which is detected by a robust instrument with a high-resolution spectrometer. The results demonstrate the high potential of the new photonic measurement and its advantages over QCM technology, such as cheap sensors (billions in one Eppendorf tube), simple pre-functionalization, much higher statistic safety by hundreds of sensors for one measurement, 5–10 times faster analysis, and that approx. 25, 000 fewer analyte molecules are needed for one sensor. In addition, the deposited molecule amount is not superposed by hydrated water as for QCM. A connection between sensors and instruments does not exist, enabling application in any transparent environment, like microfluidics, drop-on slides, Petri dishes, well plates, cell culture vasculature, etc.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2024-11-19
DOI
https://doi.org/10.3390/photonics11111087
Primary Topic
Semiconductor materials and devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Investigation of Layer-by-Layer Deposition and Dissolution Kinetics by New Label-Free Analytics Based on Low-Q-Whispering Gallery Modes

Lars Dähne, Mateusz Olszyna, Algi Domaç, J. Zimmer
Photonics
Semiconductor materials and devices
article

Quantitative Investigation of Layer-by-Layer Deposition and Dissolution Kinetics by New Label-Free Analytics Based on Low-Q-Whispering Gallery Modes

Lars Dähne, Mateusz Olszyna, Algi Domaç, J. Zimmer
article en

Abstract

A new instrument for label-free measurements based on optical Low-Q Whispering Gallery Modes (WGMs) for various applications is used for a detailed study of the deposition and release of Layer-by-Layer polymer coatings. The two selected coating pairs interact either via hydrogen bonding or electrostatic interactions. Their assembly was followed by common Quartz Crystal Microbalance (QCM) technology and the Low-Q WGMs. In contrast to planar QCM sensor chips of 1 cm, the WGM sensors are fluorescent spherical beads with diameters of 10.2 µm, enabling the detection of analyte quantities in the femtogram range in tiny volumes. The beads, with a very smooth surface and high refractive index, act as resonators for circular light waves that can revolve up to 10,000 times within the bead. The WGM frequencies are highly sensitive to changes in particle diameter and the refractive index of the surrounding medium. Hence, the adsorption of molecules shifts the resonance frequency, which is detected by a robust instrument with a high-resolution spectrometer. The results demonstrate the high potential of the new photonic measurement and its advantages over QCM technology, such as cheap sensors (billions in one Eppendorf tube), simple pre-functionalization, much higher statistic safety by hundreds of sensors for one measurement, 5–10 times faster analysis, and that approx. 25, 000 fewer analyte molecules are needed for one sensor. In addition, the deposited molecule amount is not superposed by hydrated water as for QCM. A connection between sensors and instruments does not exist, enabling application in any transparent environment, like microfluidics, drop-on slides, Petri dishes, well plates, cell culture vasculature, etc.

PhotonicsVol. 11(11)
Northwestern University (US), Surflay Nanotec (Germany) (DE)
Clean water and sanitation
Openalex Percentile: Top 82%
Semiconductor materials and devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.