Characterization of the response of a well chamber to different models of Ir-192 sources for HDR brachytherapy

The determination of the reference air kerma rate (KR) with well chambers calibrated using a different model of source than desired can lead to significant errors, affecting both radiological traceability institutions and healthcare facilities. This study employs the methodology proposed by SHIPLEY et al. (2015) with the PTW T33005 well chamber model and six models of HDR brachytherapy sources (microSelectron v.1; microSelectron v.2; Flexisource; GammaMed Plus; BEBIG GI192M11; Varisource VS2000) to derive correction factors for source geometry (KSG). These factors adjust the chamber calibration factor for air kerma (NK) to the source model under measurement. The methodology relies on simulating the chamber response to sources using the Monte Carlo Method (MC), specifically utilizing the MCNPX code. Both the source and well chamber models were validated by comparing dosimetric parameters from TG-43 and simulated calibration factors (MCNK) with literature-derived reference values. The normalized KSG values, relative to the microSelectron v.1 source, agree with reference values, demonstrating the methodology's applicability across various chamber models, sources, and MC codes. The corrections ranged from 0.984 to 1.001, with the most significant correction observed for the Varisource VS2000 source, yielding KSG = 0.984, corresponding to a -1.6% correction.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2024-11-19
DOI
https://doi.org/10.15392/2319-0612.2024.2436
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of the response of a well chamber to different models of Ir-192 sources for HDR brachytherapy

Alexandre Bernardino, A. Silva, Inayá Lima, Izabella Souza et al.
Brazilian Journal of Radiation Sciences
Photoacoustic and Ultrasonic Imaging
article

Characterization of the response of a well chamber to different models of Ir-192 sources for HDR brachytherapy

Alexandre Bernardino, A. Silva, Inayá Lima, Izabella Souza, Thais Hauradou
article en

Abstract

The determination of the reference air kerma rate (KR) with well chambers calibrated using a different model of source than desired can lead to significant errors, affecting both radiological traceability institutions and healthcare facilities. This study employs the methodology proposed by SHIPLEY et al. (2015) with the PTW T33005 well chamber model and six models of HDR brachytherapy sources (microSelectron v.1; microSelectron v.2; Flexisource; GammaMed Plus; BEBIG GI192M11; Varisource VS2000) to derive correction factors for source geometry (KSG). These factors adjust the chamber calibration factor for air kerma (NK) to the source model under measurement. The methodology relies on simulating the chamber response to sources using the Monte Carlo Method (MC), specifically utilizing the MCNPX code. Both the source and well chamber models were validated by comparing dosimetric parameters from TG-43 and simulated calibration factors (MCNK) with literature-derived reference values. The normalized KSG values, relative to the microSelectron v.1 source, agree with reference values, demonstrating the methodology's applicability across various chamber models, sources, and MC codes. The corrections ranged from 0.984 to 1.001, with the most significant correction observed for the Varisource VS2000 source, yielding KSG = 0.984, corresponding to a -1.6% correction.

Brazilian Journal of Radiation SciencesVol. 12(3A (Suppl.))
Universidade Federal do Rio de Janeiro (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 81%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of the response of a well chamber to different models of Ir-192 sources for HDR brachytherapy — Alexandre Bernardino, A. Silva, et al. · Brazilian Journal of Radiation Sciences (2024) | TGRS Research Map | TGRS