Room temperature quantitative liquid concentration device and application to interleukins analysis in a B-cell culture medium

In biological analysis and medical diagnosis, there is an increasing demand for improving the lower detection limit without deteriorating the quantitativity; however, it is usually challenging. In this study, we utilized a cyclone flow device and established a liquid concentration method. An air cyclone flow induced a liquid cyclone flow in the concentration devices and enhanced the air/liquid interface area, which allowed an effective concentration of liquid from mL to mL at room temperature. The heating temperature and actual temperature inside the liquid were investigated to know the cooling effect of evaporation. The collection efficiency of larger than 98% was confirmed with a standard solution. Finally, the analytical procedure to realize a quantitative concentration was established, and the concentration and quantification of interleukins (IL-8, IL-17, and IL-23) from the supernatant of the B-cell culture medium was demonstrated. The B-cell was stimulated with CD40L, and the supernatant was concentrated 27 times at maximum.

Authors

Institutions

Publication Details

Journal
Analytical Sciences
Published
2024-11-19
DOI
https://doi.org/10.1007/s44211-024-00688-3
Citations
1
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Room temperature quantitative liquid concentration device and application to interleukins analysis in a B-cell culture medium

Ayumi Yoshizaki, Hidekatsu Tazawa, Kazuma Mawatari, Ruriko Kawanabe
1 citations
Analytical Sciences
Protein purification and stability
0.23
article

Room temperature quantitative liquid concentration device and application to interleukins analysis in a B-cell culture medium

Ayumi Yoshizaki, Hidekatsu Tazawa, Kazuma Mawatari, Ruriko Kawanabe
article en
1 citations

Abstract

In biological analysis and medical diagnosis, there is an increasing demand for improving the lower detection limit without deteriorating the quantitativity; however, it is usually challenging. In this study, we utilized a cyclone flow device and established a liquid concentration method. An air cyclone flow induced a liquid cyclone flow in the concentration devices and enhanced the air/liquid interface area, which allowed an effective concentration of liquid from mL to mL at room temperature. The heating temperature and actual temperature inside the liquid were investigated to know the cooling effect of evaporation. The collection efficiency of larger than 98% was confirmed with a standard solution. Finally, the analytical procedure to realize a quantitative concentration was established, and the concentration and quantification of interleukins (IL-8, IL-17, and IL-23) from the supernatant of the B-cell culture medium was demonstrated. The B-cell was stimulated with CD40L, and the supernatant was concentrated 27 times at maximum.

Analytical SciencesVol. 41(2)
Waseda University (JP), University of Tokyo Hospital (JP), The University of Tokyo (JP)
Japan International Cooperation Agency, University of Tokyo, Japan Science and Technology Agency, Science and Technology Research Partnership for Sustainable Development
Clean water and sanitation
Openalex Percentile: Top 41%
Protein purification and stability
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.