Comparative Thermal Performance Analysis of Coaxial Versus Conventional Pipes in District Heating Distribution Systems

District heating systems play a pivotal role in providing efficient and sustainable heating solutions for urban areas. In this sense, district heating systems that use geothermal resources have been gaining prominence in recent years, due to the non-intermittent nature of their application, among many other reasons. The present study investigates the thermal performance of novel coaxial pipes in comparison to conventional pipes within district heating distribution networks supplied by geothermal energy. Through experimental simulation and analysis, key thermal parameters such as heat transfer efficiency, thermal losses, and overall system effectiveness are evaluated through laboratory tests developed on a scale model. Experimental analysis concludes that, at a laboratory scale, heat energy efficiency can be improved by around 37% regarding the traditional geothermal distribution network. This improvement translates into a significant economic and environmental impact that has a direct influence on the viability of this type of system in different application scenarios. The results highlight the potential benefits of coaxial pipe designs in enhancing heat transfer efficiency and minimizing thermal losses, thus offering insights for optimizing geothermal district heating infrastructure for improved energy efficiency and sustainability. The novelty of this study lies in the innovative design and experimental validation of coaxial pipes, which demonstrate a 37% improvement in heat energy efficiency over conventional pipe designs in geothermal district heating systems, offering a breakthrough in optimizing heat transfer and minimizing thermal losses.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2024-11-19
DOI
https://doi.org/10.3390/su162210093
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Thermal Performance Analysis of Coaxial Versus Conventional Pipes in District Heating Distribution Systems

Cristina Sáez Blázquez, Enrique González-González, Miguel Ángel Maté‐González, Arturo Farfán Martín et al.
Sustainability
Integrated Energy Systems Optimization
article

Comparative Thermal Performance Analysis of Coaxial Versus Conventional Pipes in District Heating Distribution Systems

Cristina Sáez Blázquez, Enrique González-González, Miguel Ángel Maté‐González, Arturo Farfán Martín, Ignacio Martín Nieto, Natalia Nuño Villanueva, Diego González‐Aguilera, Viviana Fernández
article en

Abstract

District heating systems play a pivotal role in providing efficient and sustainable heating solutions for urban areas. In this sense, district heating systems that use geothermal resources have been gaining prominence in recent years, due to the non-intermittent nature of their application, among many other reasons. The present study investigates the thermal performance of novel coaxial pipes in comparison to conventional pipes within district heating distribution networks supplied by geothermal energy. Through experimental simulation and analysis, key thermal parameters such as heat transfer efficiency, thermal losses, and overall system effectiveness are evaluated through laboratory tests developed on a scale model. Experimental analysis concludes that, at a laboratory scale, heat energy efficiency can be improved by around 37% regarding the traditional geothermal distribution network. This improvement translates into a significant economic and environmental impact that has a direct influence on the viability of this type of system in different application scenarios. The results highlight the potential benefits of coaxial pipe designs in enhancing heat transfer efficiency and minimizing thermal losses, thus offering insights for optimizing geothermal district heating infrastructure for improved energy efficiency and sustainability. The novelty of this study lies in the innovative design and experimental validation of coaxial pipes, which demonstrate a 37% improvement in heat energy efficiency over conventional pipe designs in geothermal district heating systems, offering a breakthrough in optimizing heat transfer and minimizing thermal losses.

SustainabilityVol. 16(22)
Universidad de Salamanca (ES), Catholic University of Ávila (ES)
European Commission, Ministerio de Ciencia e Innovación, European Regional Development Fund, Agencia Estatal de Investigación
Openalex Percentile: Top 82%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.