A high sensitivity, low cost and fully decoupled multi-axis capacitive tactile force sensor for robotic surgical systems

This paper presents the design of a multi-axis capacitive tactile force sensor with a fully decoupled output response for input normal and shear forces. A patterned elastomer is used as a dielectric layer between capacitive electrodes of the sensor that allows to achieve relatively higher sensitivity. The sensor is fabricated utilizing a low-cost rapid prototyping technique and is characterized for normal and shear forces in the range of 0 ~ 10 N and 0 ~ 3.1 N respectively. The achieved force sensitivity for the normal axis is 2.03%/N and for shear axes is 1.67%/N. The difference between the estimated force from the sensor and actual force applied is negligible, which demonstrates the accuracy of the sensor. The reliability of the sensor is analysed by performing hysteresis and repeatability tests. The hysteresis error is found to be 4.94% and 4.69% for normal and shear forces respectively. The repeatability error of the sensor is less than 5%, which shows the stability of the sensor. The high sensitivity, linear output response, high force measurement range, reliability and low cost make the proposed tactile sensor suitable for the force feedback in the robotic surgical systems.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-11-19
DOI
https://doi.org/10.1371/journal.pone.0313737
Citations
7
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
1.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A high sensitivity, low cost and fully decoupled multi-axis capacitive tactile force sensor for robotic surgical systems

Muhammad Rehan, Hassan Elahi, Mohsin Islam Tiwana, Sajid Hussain et al.
7 citations
PLoS ONE
Advanced Sensor and Energy Harvesting Materials
1.29
article

A high sensitivity, low cost and fully decoupled multi-axis capacitive tactile force sensor for robotic surgical systems

Muhammad Rehan, Hassan Elahi, Mohsin Islam Tiwana, Sajid Hussain, Muhammad Mubasher Saleem
article en
7 citations

Abstract

This paper presents the design of a multi-axis capacitive tactile force sensor with a fully decoupled output response for input normal and shear forces. A patterned elastomer is used as a dielectric layer between capacitive electrodes of the sensor that allows to achieve relatively higher sensitivity. The sensor is fabricated utilizing a low-cost rapid prototyping technique and is characterized for normal and shear forces in the range of 0 ~ 10 N and 0 ~ 3.1 N respectively. The achieved force sensitivity for the normal axis is 2.03%/N and for shear axes is 1.67%/N. The difference between the estimated force from the sensor and actual force applied is negligible, which demonstrates the accuracy of the sensor. The reliability of the sensor is analysed by performing hysteresis and repeatability tests. The hysteresis error is found to be 4.94% and 4.69% for normal and shear forces respectively. The repeatability error of the sensor is less than 5%, which shows the stability of the sensor. The high sensitivity, linear output response, high force measurement range, reliability and low cost make the proposed tactile sensor suitable for the force feedback in the robotic surgical systems.

PLoS ONEVol. 19(11)
National University of Sciences and Technology (PK)
Affordable and clean energy
Openalex Percentile: Top 21%
Advanced Sensor and Energy Harvesting Materials
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A high sensitivity, low cost and fully decoupled multi-axis capacitive tactile force sensor for robotic surgical systems — Muhammad Rehan, Hassan Elahi, et al. · PLoS ONE (2024) | TGRS Research Map | TGRS