Estimation of Glycated Hemoglobin Using Multiwavelength Photoplethysmography Signal

Diabetes mellitus is a metabolic disorder, and pro-longed exposure to sugar molecules in the blood stream results in hemoglobin glycation. It is measured in percentage of glycated hemoglobin <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\mathbf{HbA}_{1\mathrm{c}})$</tex> cells in all hemoglobin cells. A suspected person may have symptoms such as abrupt weight loss, increased thirst and hunger, frequent urination, etc. The conventional method requires invasive blood testing methods performed in specific laboratories. The work proposes a non-invasive solution to measure <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\%\mathbf{HbA}_{1\mathrm{c}}$</tex> using Photoplethysmography (PPG) signal. A PPG sensor records these signals at two distinct wavelengths, i.e., green and infrared (IR). After initial preprocessing and feature extraction, a random forest regressor estimates the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\%\mathbf{HbA}_{1\mathrm{c}}$</tex>. The study is validated with recording of 9 subjects. The estimation of the results shows a high degree of correlation with 0.907 and 0.952 pearson's correlation coefficient <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{r}$</tex> values for the reflective PPG signal. These calculated values are compared with the true <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\%\mathbf{HbA}_{1\mathrm{c}}$</tex> values. The results show a close approximation of the calculated values to the true values. Also, the error analysis is performed in terms of mean squared and root mean squared error.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/tensymp61132.2024.10752123
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of Glycated Hemoglobin Using Multiwavelength Photoplethysmography Signal

Surendra Kumar Saini, Ravi Kumar Maddila, Santosh Kumar Tiwari, Anil Sharma
1 citations
Non-Invasive Vital Sign Monitoring
0.18
article

Estimation of Glycated Hemoglobin Using Multiwavelength Photoplethysmography Signal

Surendra Kumar Saini, Ravi Kumar Maddila, Santosh Kumar Tiwari, Anil Sharma
article en
1 citations

Abstract

Diabetes mellitus is a metabolic disorder, and pro-longed exposure to sugar molecules in the blood stream results in hemoglobin glycation. It is measured in percentage of glycated hemoglobin <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\mathbf{HbA}_{1\mathrm{c}})$</tex> cells in all hemoglobin cells. A suspected person may have symptoms such as abrupt weight loss, increased thirst and hunger, frequent urination, etc. The conventional method requires invasive blood testing methods performed in specific laboratories. The work proposes a non-invasive solution to measure <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\%\mathbf{HbA}_{1\mathrm{c}}$</tex> using Photoplethysmography (PPG) signal. A PPG sensor records these signals at two distinct wavelengths, i.e., green and infrared (IR). After initial preprocessing and feature extraction, a random forest regressor estimates the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\%\mathbf{HbA}_{1\mathrm{c}}$</tex>. The study is validated with recording of 9 subjects. The estimation of the results shows a high degree of correlation with 0.907 and 0.952 pearson's correlation coefficient <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{r}$</tex> values for the reflective PPG signal. These calculated values are compared with the true <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\%\mathbf{HbA}_{1\mathrm{c}}$</tex> values. The results show a close approximation of the calculated values to the true values. Also, the error analysis is performed in terms of mean squared and root mean squared error.

Malaviya National Institute of Technology Jaipur (IN)
Openalex Percentile: Top 51%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Estimation of Glycated Hemoglobin Using Multiwavelength Photoplethysmography Signal — Surendra Kumar Saini, Ravi Kumar Maddila, et al. · (2024) | TGRS Research Map | TGRS