Implementation of Protection Features for a Modular Bidirectional Solid-State Battery Disconnector

The growing adoption of batteries with high voltages (HVs), ranging from 400 to 800 V, in electric vehicles (EVs), coupled with the high load demand, necessitates enhanced circuit protection against overcurrent events and short-circuit faults. This is crucial to prevent damage to the connected wiring harness, battery, and loads. Conventional approaches like thermal fuses, dc contactors, and pyrofuses are constrained by factors such as slow response times, degradation with fault occurrences, and the need for regular maintenance and replacement, respectively. In response to these limitations, this article proposes the introduction of a compact, resettable, and bidirectional solid-state dc disconnector (SSD) as a solution to overcome these challenges. The proposed disconnector is based on an anti-series connection of silicon carbide (SiC) switches, which offer fast response times and operate under a wide voltage range. It can differentiate between overcurrent events and short-circuit faults and can be configured for different trip current threshold values. In addition to the current-analog-to-digital converter (ADC)-based sampling method for overcurrent detection, analog hardware path-based short-circuit detection has been implemented for faster fault interruption. A variable inverse time-current characteristic trip curve, based on the I2t profile, has been implemented to prevent unintentional tripping during transient inrush current events. The article also proposes a modular SSD to enhance reliability and scalability for high-current operation using low-power-rated devices and low-current-rated sensors in each module. The performance of the proposed SSD, with each module designed for a system rating of 800 V/30 A, has been experimentally validated using both single- and two-module operations for protection against overcurrent, short-circuit faults, and undervoltage protection.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Emerging and Selected Topics in Power Electronics
Published
2024-11-19
DOI
https://doi.org/10.1109/jestpe.2024.3502157
Citations
5
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
1.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of Protection Features for a Modular Bidirectional Solid-State Battery Disconnector

Daniel Dsa, Edivan Laércio Carvalho, Satish Naik Banavath, Abhinav Chinnusamy
5 citations
IEEE Journal of Emerging and Selected Topics in Power Electronics
Advanced Battery Technologies Research
1.02
article

Implementation of Protection Features for a Modular Bidirectional Solid-State Battery Disconnector

Daniel Dsa, Edivan Laércio Carvalho, Satish Naik Banavath, Abhinav Chinnusamy
article en
5 citations

Abstract

The growing adoption of batteries with high voltages (HVs), ranging from 400 to 800 V, in electric vehicles (EVs), coupled with the high load demand, necessitates enhanced circuit protection against overcurrent events and short-circuit faults. This is crucial to prevent damage to the connected wiring harness, battery, and loads. Conventional approaches like thermal fuses, dc contactors, and pyrofuses are constrained by factors such as slow response times, degradation with fault occurrences, and the need for regular maintenance and replacement, respectively. In response to these limitations, this article proposes the introduction of a compact, resettable, and bidirectional solid-state dc disconnector (SSD) as a solution to overcome these challenges. The proposed disconnector is based on an anti-series connection of silicon carbide (SiC) switches, which offer fast response times and operate under a wide voltage range. It can differentiate between overcurrent events and short-circuit faults and can be configured for different trip current threshold values. In addition to the current-analog-to-digital converter (ADC)-based sampling method for overcurrent detection, analog hardware path-based short-circuit detection has been implemented for faster fault interruption. A variable inverse time-current characteristic trip curve, based on the I2t profile, has been implemented to prevent unintentional tripping during transient inrush current events. The article also proposes a modular SSD to enhance reliability and scalability for high-current operation using low-power-rated devices and low-current-rated sensors in each module. The performance of the proposed SSD, with each module designed for a system rating of 800 V/30 A, has been experimentally validated using both single- and two-module operations for protection against overcurrent, short-circuit faults, and undervoltage protection.

IEEE Journal of Emerging and Selected Topics in Power ElectronicsVol. 13(3)
Tallinn University of Technology (EE), Indian Institute of Technology Dharwad (IN)
Science and Engineering Research Board
Affordable and clean energy
Openalex Percentile: Top 24%
Advanced Battery Technologies Research
1.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.