Shock Index as a Predictor of Postpartum Hemorrhage After Vaginal Delivery: Secondary Analysis of a Multicenter Randomized Controlled Trial

( BJOG. 2024;131:343–352. doi: 10.1111/1471-0528.17634) A reliable predictive indicator of postpartum hemorrhage (PPH) could be a significant medical advance. Shock index (SI) is a measurement dividing heart rate (bpm) by systolic blood pressure (mmHg), with a healthy individual usually between 0.5 and 0.7 and the cutoff, where morbidity and mortality is expected, at 0.9. Elevated SI values have been associated with various cardiovascular conditions including hypovolemia and left heart dysfunction. Previous studies have shown values in the immediate postpartum period to range from 0.5 to 0.9, although these studies excluded women who experienced PPH. Additional research suggests the potential for SI to be used as an early sign of PPH, with a range of 0.9 and 1.0; however, the SI included for each patient was their highest in the postpartum period, which technically means the value is being used as a detection tool rather than a predictor. SI is currently recommended as a tool for PPH management.

Authors

Institutions

Publication Details

Journal
Obstetric Anesthesia Digest
Published
2024-11-19
DOI
https://doi.org/10.1097/01.aoa.0001080224.55575.0e
Primary Topic
Maternal and fetal healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shock Index as a Predictor of Postpartum Hemorrhage After Vaginal Delivery: Secondary Analysis of a Multicenter Randomized Controlled Trial

Catherine Deneux‐Tharaux, Hugo Madar, Loı̈c Sentilhes
Obstetric Anesthesia Digest
Maternal and fetal healthcare
article

Shock Index as a Predictor of Postpartum Hemorrhage After Vaginal Delivery: Secondary Analysis of a Multicenter Randomized Controlled Trial

Catherine Deneux‐Tharaux, Hugo Madar, Loı̈c Sentilhes
article en

Abstract

( BJOG. 2024;131:343–352. doi: 10.1111/1471-0528.17634) A reliable predictive indicator of postpartum hemorrhage (PPH) could be a significant medical advance. Shock index (SI) is a measurement dividing heart rate (bpm) by systolic blood pressure (mmHg), with a healthy individual usually between 0.5 and 0.7 and the cutoff, where morbidity and mortality is expected, at 0.9. Elevated SI values have been associated with various cardiovascular conditions including hypovolemia and left heart dysfunction. Previous studies have shown values in the immediate postpartum period to range from 0.5 to 0.9, although these studies excluded women who experienced PPH. Additional research suggests the potential for SI to be used as an early sign of PPH, with a range of 0.9 and 1.0; however, the SI included for each patient was their highest in the postpartum period, which technically means the value is being used as a detection tool rather than a predictor. SI is currently recommended as a tool for PPH management.

Obstetric Anesthesia DigestVol. 44(4)
Université Paris Cité (FR), Sorbonne Paris Cité (FR)
Good health and well-being
Openalex Percentile: Top 68%
Maternal and fetal healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.