Synthesis and modification of nanofiltration membranes with dendrimer-modified graphene oxide to remove lead and cadmium ions from aqueous solutions

This study explored the use of graphene oxide modified with dendrimer (GO/MDA) to enhance the hydrophilicity and reduce the clogging of nanofiltration membranes, aiming to remove lead and cadmium from aqueous solutions. The synthesis involved multiple steps for creating graphene oxide (GO) nanoparticles and dendrimer (MDA), with FT-IR and EDX tests confirming the successful fabrication of GO/MDA and its application in nanofiltration membranes. Four types of membranes were designated based on the concentration of GO/MDA used: nanofiltration without nanoparticles (NF), nanofiltration with 0.25% weight of nanoparticles (NF-0.25), nanofiltration with 0.5% weight of nanoparticles (NF-0.5), and nanofiltration with 1% weight of nanoparticles (NF-1). The results showed a significant decrease in contact angle from 68.2° to 51.6° with the increase of GO/MDA concentration from 0.25% to 1%, illustrating improved hydrophilicity. Moreover, the pure water flow rate increased, with the NF-1 membrane achieving the highest flow rate of 121 L/m 2 .h, compared to 86 L/m 2 .h for the standard NF membrane. The study also established that the removal efficiencies for lead and cadmium improved with rising pH levels, peaking at pH 6, where the NF-0.5 membrane achieved optimal removal rates of 89.45% for Pb 2 ⁺ and 92.58% for Cd 2 ⁺. Additionally, the incorporation of GO/MDA nanoparticles effectively reduced irreversible fouling, with the NF-0.5 membrane displaying a remarkable flux recovery percentage of 97.21%. Overall, the findings confirm that the incorporation of GO/MDA nanoparticles successfully enhanced the performance of nanofiltration membranes in removing heavy metals.

Authors

Institutions

Publication Details

Journal
Cleaner Engineering and Technology
Published
2024-11-19
DOI
https://doi.org/10.1016/j.clet.2024.100843
Citations
4
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis and modification of nanofiltration membranes with dendrimer-modified graphene oxide to remove lead and cadmium ions from aqueous solutions

S.A. Hassanzadeh-Tabrizi, Farham Aminsharei, Elham Ameri, A. Malekzadeh et al.
4 citations
Cleaner Engineering and Technology
Membrane Separation Technologies
0.81
article

Synthesis and modification of nanofiltration membranes with dendrimer-modified graphene oxide to remove lead and cadmium ions from aqueous solutions

S.A. Hassanzadeh-Tabrizi, Farham Aminsharei, Elham Ameri, A. Malekzadeh, Saeed Niazkhani
article en
4 citations

Abstract

This study explored the use of graphene oxide modified with dendrimer (GO/MDA) to enhance the hydrophilicity and reduce the clogging of nanofiltration membranes, aiming to remove lead and cadmium from aqueous solutions. The synthesis involved multiple steps for creating graphene oxide (GO) nanoparticles and dendrimer (MDA), with FT-IR and EDX tests confirming the successful fabrication of GO/MDA and its application in nanofiltration membranes. Four types of membranes were designated based on the concentration of GO/MDA used: nanofiltration without nanoparticles (NF), nanofiltration with 0.25% weight of nanoparticles (NF-0.25), nanofiltration with 0.5% weight of nanoparticles (NF-0.5), and nanofiltration with 1% weight of nanoparticles (NF-1). The results showed a significant decrease in contact angle from 68.2° to 51.6° with the increase of GO/MDA concentration from 0.25% to 1%, illustrating improved hydrophilicity. Moreover, the pure water flow rate increased, with the NF-1 membrane achieving the highest flow rate of 121 L/m 2 .h, compared to 86 L/m 2 .h for the standard NF membrane. The study also established that the removal efficiencies for lead and cadmium improved with rising pH levels, peaking at pH 6, where the NF-0.5 membrane achieved optimal removal rates of 89.45% for Pb 2 ⁺ and 92.58% for Cd 2 ⁺. Additionally, the incorporation of GO/MDA nanoparticles effectively reduced irreversible fouling, with the NF-0.5 membrane displaying a remarkable flux recovery percentage of 97.21%. Overall, the findings confirm that the incorporation of GO/MDA nanoparticles successfully enhanced the performance of nanofiltration membranes in removing heavy metals.

Cleaner Engineering and TechnologyVol. 23
Islamic Azad University of Gachsaran (IR), Islamic Azad University of Najafabad (IR)
Clean water and sanitation
Openalex Percentile: Top 28%
Membrane Separation Technologies
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.