Applicability of a green nanocomposite consists of reduced graphene oxide and β-cyclodextrin for electrochemical tracing of methadone in human biofluids validated by international greenness indexes

The developed sensor electrochemically detected MET at 0.8 V in buffer phosphate with a pH value of 7 under a wide linear concentration range (1 μM-830 μM), including a MET concentration level alarmed based on the consumer opioid tolerance according to the WHO's report. The limit of detection and analytical sensitivity values were calculated to be 333.33 nM and 0.0502 μA μM<sup>-1</sup>. The acceptable performance of the sensor to detect MET in various real human biofluids including serum, urine, and saliva samples, which is a bonus for the real-time and on-site measurement of MET, may open up a route for noninvasive routine tests in clinical samples. Moreover, the greenness profile of this strategy has been well evaluated by two common international metrics.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-11-19
DOI
https://doi.org/10.1016/j.heliyon.2024.e40505
Citations
9
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applicability of a green nanocomposite consists of reduced graphene oxide and β-cyclodextrin for electrochemical tracing of methadone in human biofluids validated by international greenness indexes

Sayyed Esmaeil Moradi, Faezeh Shahdost-fard, Ardeshir Shokrollahi
9 citations
Heliyon
Electrochemical sensors and biosensors
1.88
article

Applicability of a green nanocomposite consists of reduced graphene oxide and β-cyclodextrin for electrochemical tracing of methadone in human biofluids validated by international greenness indexes

Sayyed Esmaeil Moradi, Faezeh Shahdost-fard, Ardeshir Shokrollahi
article en
9 citations

Abstract

The developed sensor electrochemically detected MET at 0.8 V in buffer phosphate with a pH value of 7 under a wide linear concentration range (1 μM-830 μM), including a MET concentration level alarmed based on the consumer opioid tolerance according to the WHO's report. The limit of detection and analytical sensitivity values were calculated to be 333.33 nM and 0.0502 μA μM<sup>-1</sup>. The acceptable performance of the sensor to detect MET in various real human biofluids including serum, urine, and saliva samples, which is a bonus for the real-time and on-site measurement of MET, may open up a route for noninvasive routine tests in clinical samples. Moreover, the greenness profile of this strategy has been well evaluated by two common international metrics.

HeliyonVol. 10(23)
Yasouj University (IR), Farhangian University (IR)
Yasouj University
Responsible consumption and production
Openalex Percentile: Top 14%
Electrochemical sensors and biosensors
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.