Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure

The accelerator-based boron neutron capture therapy (BNCT) system has been approved for specific cases covered by health insurance, and clinical trials for new cases in Japan are currently being conducted on other systems. Owing to the progress of accelerator-based BNCT, the operation of medical physics must be rendered more efficient. A water phantom is used for the quality assurance (QA) of the BNCT beam output procedure; however, a solid phantom is preferred for routine QA because of its ease of use. Additionally, because water phantoms cannot be readily used in some facilities owing to structural problems, solid phantoms are preferred for unified measurements at different facilities to compare beam outputs. In this study, we perform irradiation tests using an acrylic phantom and verify that an acrylic phantom can be used for QA. The distribution of thermal neutron flux and gamma-ray dose rate inside the acrylic phantom are evaluated through experiments and simulations. The results indicate that the acrylic phantom is suitable for routine QA and for comparing beam outputs among different systems. In the future, the same irradiation tests will be conducted at other facilities.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research
Published
2024-11-19
DOI
https://doi.org/10.1093/jrr/rrae089
Citations
3
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure

Satoshi Nakamura, Naonori Hu, Hiroki Tanaka, Nishiki Matsubayashi et al.
3 citations
Journal of Radiation Research
Boron Compounds in Chemistry
1.21
article

Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure

Satoshi Nakamura, Naonori Hu, Hiroki Tanaka, Nishiki Matsubayashi, Hiroaki Kumada, Akihiko Masuda, Takushi Takata, Akinori Sasaki
article en
3 citations

Abstract

The accelerator-based boron neutron capture therapy (BNCT) system has been approved for specific cases covered by health insurance, and clinical trials for new cases in Japan are currently being conducted on other systems. Owing to the progress of accelerator-based BNCT, the operation of medical physics must be rendered more efficient. A water phantom is used for the quality assurance (QA) of the BNCT beam output procedure; however, a solid phantom is preferred for routine QA because of its ease of use. Additionally, because water phantoms cannot be readily used in some facilities owing to structural problems, solid phantoms are preferred for unified measurements at different facilities to compare beam outputs. In this study, we perform irradiation tests using an acrylic phantom and verify that an acrylic phantom can be used for QA. The distribution of thermal neutron flux and gamma-ray dose rate inside the acrylic phantom are evaluated through experiments and simulations. The results indicate that the acrylic phantom is suitable for routine QA and for comparing beam outputs among different systems. In the future, the same irradiation tests will be conducted at other facilities.

Journal of Radiation ResearchVol. 66(1)
University of Tsukuba (JP), Kyoto University (JP), Kansai Vocational College of Medicine (JP), National Cancer Center (US), National Institute of Advanced Industrial Science and Technology (JP), Osaka University of Pharmaceutical Sciences (JP)
Openalex Percentile: Top 19%
Boron Compounds in Chemistry
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure — Satoshi Nakamura, Naonori Hu, et al. · Journal of Radiation Research (2024) | TGRS Research Map | TGRS