Multimodal assessment of brain stiffness variation in healthy subjects using magnetic resonance elastography and ultrasound time-harmonic elastography

Magnetic resonance elastography (MRE) is a noninvasive brain stiffness mapping method. Ultrasound-based transtemporal time-harmonic elastography (THE) is emerging as a cost-effective, fast alternative that has potential applications for bedside monitoring of intracranial pressure. We aim to investigate the accuracy of THE in comparison to MRE performed in the brain. Ten healthy volunteers (25-40 years old) underwent multifrequency MRE (20-35 Hz) and THE (27-56 Hz). Fiducial-marker-based optical tracking of the ultrasound field of view was used to align THE to 3D MRE. THE- and MRE-derived shear wave speed (SWS) was determined as a measure of brain stiffness and averaged within regions of various depths for cross-modality correlation analysis. MRE-measured SWS ranged from 1.0 to 1.3 m/s and was negatively correlated with age (R<sup>2</sup> = 0.44, p = 0.035). After registration of both modalities, SWS values were linearly correlated (MRE: 1.14 ± 0.08 m/s, THE: 1.13 ± 0.10 m/s; R<sup>2</sup> = 0.62, p = 0.007). Best agreement between modalities was achieved at depths of 40-60 mm, suggesting this range provides a viable trade-off between ultrasound attenuation and near-field bias. Similar brain regions can be consistently measured with both elastography modalities, despite the regional and individual variations of stiffness. Transtemporal THE yields stiffness values in a range similar to those obtained with more expensive MRE.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-19
DOI
https://doi.org/10.1038/s41598-024-79991-y
Citations
2
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multimodal assessment of brain stiffness variation in healthy subjects using magnetic resonance elastography and ultrasound time-harmonic elastography

Heiko Tzschätzsch, Spencer T. Brinker, Tom Meyer, Ingolf Sack et al.
2 citations
Scientific Reports
Ultrasound Imaging and Elastography
0.81
article

Multimodal assessment of brain stiffness variation in healthy subjects using magnetic resonance elastography and ultrasound time-harmonic elastography

Heiko Tzschätzsch, Spencer T. Brinker, Tom Meyer, Ingolf Sack, Stefan Klemmer Chandía, Jakob Schattenfroh
article en
2 citations

Abstract

Magnetic resonance elastography (MRE) is a noninvasive brain stiffness mapping method. Ultrasound-based transtemporal time-harmonic elastography (THE) is emerging as a cost-effective, fast alternative that has potential applications for bedside monitoring of intracranial pressure. We aim to investigate the accuracy of THE in comparison to MRE performed in the brain. Ten healthy volunteers (25-40 years old) underwent multifrequency MRE (20-35 Hz) and THE (27-56 Hz). Fiducial-marker-based optical tracking of the ultrasound field of view was used to align THE to 3D MRE. THE- and MRE-derived shear wave speed (SWS) was determined as a measure of brain stiffness and averaged within regions of various depths for cross-modality correlation analysis. MRE-measured SWS ranged from 1.0 to 1.3 m/s and was negatively correlated with age (R<sup>2</sup> = 0.44, p = 0.035). After registration of both modalities, SWS values were linearly correlated (MRE: 1.14 ± 0.08 m/s, THE: 1.13 ± 0.10 m/s; R<sup>2</sup> = 0.62, p = 0.007). Best agreement between modalities was achieved at depths of 40-60 mm, suggesting this range provides a viable trade-off between ultrasound attenuation and near-field bias. Similar brain regions can be consistently measured with both elastography modalities, despite the regional and individual variations of stiffness. Transtemporal THE yields stiffness values in a range similar to those obtained with more expensive MRE.

Scientific ReportsVol. 14(1)
Yale University (US), Humboldt-Universität zu Berlin (DE), Freie Universität Berlin (DE), Charité - Universitätsmedizin Berlin (DE)
Deutsche Forschungsgemeinschaft, Charité – Universitätsmedizin Berlin
Openalex Percentile: Top 24%
Ultrasound Imaging and Elastography
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.