Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners

To better understand the bending performance of rectangular high-strength steel fiber-reinforced concrete (HSFRC)-filled steel tubular (HSFRCFST) beams with internal stiffeners, ten beams were subjected to a four-point bending test. The primary considerations were the strength grade of the HSFRC, the steel fiber content, the internal stiffener type, and the circular hole spacing of the perfobond stiffener. The moment–curvature and flexural load–deflection curves were calculated. The mode of failure and the distribution of cracks of the infill HSFRC were observed. The presence of steel fibers greatly improved the bending stiffness and moment capacity of HSFRCFST beams, with the optimal effect happening at a steel fiber content of 1.2% by volume, according to the experimental findings. The type of stiffener influenced the failure modes of the exterior rectangular steel tube, which were unaffected by the compressive strength of the infill HSFRC. On the tension surface of HSFRCFST beams, the crack spacing of the infill HSFRC was virtually identical to the circular hole spacing of perfobond stiffeners. When the circular hole spacing was between two and three times the diameter, the perfobond stiffener worked best with the infill HSFRC. The test beams’ ductility index was greater than 1.16, indicating good ductility. The test beams’ rotational capacities ranged from 6.26 to 13.20, which were greater than 3.0 and met the requirements of the specification. The experimental results demonstrate that a reasonable design of the steel fiber content and the spacing between circular holes of perfobond stiffeners can significantly improve the bending resistance of rectangular HSFRCFST beams. This provides relevant parameter design suggestions for improving the ductility and bearing capacity of steel fiber-reinforced concrete beams in practical construction. Finally, a design formula for the moment capacity of rectangular HSFRCFST beams with stiffeners is presented, which corresponds well with the experimental findings.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-19
DOI
https://doi.org/10.3390/buildings14113678
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners

S Liu, Shangyu Li, Shunbo Zhao, Xiaoke Li et al.
1 citations
Buildings
Structural Load-Bearing Analysis
0.26
article

Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners

S Liu, Shangyu Li, Shunbo Zhao, Xiaoke Li, Yongjian Liu, Zhou Ji
article en
1 citations

Abstract

To better understand the bending performance of rectangular high-strength steel fiber-reinforced concrete (HSFRC)-filled steel tubular (HSFRCFST) beams with internal stiffeners, ten beams were subjected to a four-point bending test. The primary considerations were the strength grade of the HSFRC, the steel fiber content, the internal stiffener type, and the circular hole spacing of the perfobond stiffener. The moment–curvature and flexural load–deflection curves were calculated. The mode of failure and the distribution of cracks of the infill HSFRC were observed. The presence of steel fibers greatly improved the bending stiffness and moment capacity of HSFRCFST beams, with the optimal effect happening at a steel fiber content of 1.2% by volume, according to the experimental findings. The type of stiffener influenced the failure modes of the exterior rectangular steel tube, which were unaffected by the compressive strength of the infill HSFRC. On the tension surface of HSFRCFST beams, the crack spacing of the infill HSFRC was virtually identical to the circular hole spacing of perfobond stiffeners. When the circular hole spacing was between two and three times the diameter, the perfobond stiffener worked best with the infill HSFRC. The test beams’ ductility index was greater than 1.16, indicating good ductility. The test beams’ rotational capacities ranged from 6.26 to 13.20, which were greater than 3.0 and met the requirements of the specification. The experimental results demonstrate that a reasonable design of the steel fiber content and the spacing between circular holes of perfobond stiffeners can significantly improve the bending resistance of rectangular HSFRCFST beams. This provides relevant parameter design suggestions for improving the ductility and bearing capacity of steel fiber-reinforced concrete beams in practical construction. Finally, a design formula for the moment capacity of rectangular HSFRCFST beams with stiffeners is presented, which corresponds well with the experimental findings.

BuildingsVol. 14(11)
North China University of Water Resources and Electric Power (CN), Chang'an University (CN)
National Natural Science Foundation of China, Chang'an University, Fundamental Research Funds for the Central Universities
Sustainable cities and communities
Openalex Percentile: Top 43%
Structural Load-Bearing Analysis
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.