Accurate Phase Calibration of Multistatic Imaging System for Medical and Industrial Applications

Multistatic imaging systems are commonly used in radar systems and microwave imaging. In these systems, many antennas are arranged three-dimensionally and connected to RF switches. The length of each transmitter (Tx) and receiver (Rx) channel differs slightly, causing artifacts in high-resolution image reconstruction. This study presents a novel method for the phase calibration of multistatic systems. This method does not require system reconstruction and can automatically perform phase calibration in a short time. This method is expected to facilitate an accurate phase measurement in multistatic systems. The approach involves phase calibration by analyzing the reflection coefficients of antenna elements in the time domain. Imaging experiments were performed on a multistatic imaging system using this calibration method, and the position and shape of a metal rod with a diameter one-fourth of a wavelength were reconstructed by simple back-projection with an accuracy beyond the diffraction limit.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-11-19
DOI
https://doi.org/10.3390/app142210671
Citations
1
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate Phase Calibration of Multistatic Imaging System for Medical and Industrial Applications

Soichiro Yamaguchi, M. Asakawa, H. Tabata
1 citations
Applied Sciences
Microwave Imaging and Scattering Analysis
0.18
article

Accurate Phase Calibration of Multistatic Imaging System for Medical and Industrial Applications

Soichiro Yamaguchi, M. Asakawa, H. Tabata
article en
1 citations

Abstract

Multistatic imaging systems are commonly used in radar systems and microwave imaging. In these systems, many antennas are arranged three-dimensionally and connected to RF switches. The length of each transmitter (Tx) and receiver (Rx) channel differs slightly, causing artifacts in high-resolution image reconstruction. This study presents a novel method for the phase calibration of multistatic systems. This method does not require system reconstruction and can automatically perform phase calibration in a short time. This method is expected to facilitate an accurate phase measurement in multistatic systems. The approach involves phase calibration by analyzing the reflection coefficients of antenna elements in the time domain. Imaging experiments were performed on a multistatic imaging system using this calibration method, and the position and shape of a metal rod with a diameter one-fourth of a wavelength were reconstructed by simple back-projection with an accuracy beyond the diffraction limit.

Applied SciencesVol. 14(22)
Kansai University (JP)
Openalex Percentile: Top 51%
Microwave Imaging and Scattering Analysis
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accurate Phase Calibration of Multistatic Imaging System for Medical and Industrial Applications — Soichiro Yamaguchi, M. Asakawa, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS