The use of point‐of‐care ultrasound for detection of retinal detachment in emergency department

Abstract Introduction Retinal detachment (RD) is an ocular emergency commonly encountered in the emergency department (ED). Point‐of‐care ultrasound (POCUS) has been proposed to rapidly identify the diagnosis. This study aimed to assess the accuracy of POCUS for detection of RD by a group of emergency physicians (EP) who had no prior experience in ocular POCUS. Methods This was a retrospective single‐center cohort study conducted between July 2023 and April 2024. All EP without any experience of POCUS in the department were invited to participate voluntarily in the study. They received a structured training session prior to the commencement of study which included a 30‐min lecture followed by a 30‐min supervised hands‐on practice on healthy individuals. All adult patients presenting to ED with acute onset flashes, floaters, and monocular visual loss were included. Patients who met one of the following criteria were excluded: pre‐existing or known RD, suspected ruptured eyeball, and unable to communicate in either Chinese or English. The final diagnosis by ophthalmologists were used as the gold standard for comparison. Results A total of 12 EP participated in the study and 89 patients were identified. Fourteen of them received the diagnosis of RD by ophthalmologists. Overall, the sensitivity of ocular POCUS was 93% (95% confidence interval (CI = 66%–100%). Specificity was 89% (95% CI = 80%–95%). The positive predictive value was 62% (95% CI = 45%–76%) and the negative predictive value was 98% (95% CI = 91%–100%). Conclusion Ocular POCUS has high sensitivity and negative predictive value for detection of RD. It is a useful and readily available diagnostic tool in ED even for EP without prior experience.

Authors

Institutions

Publication Details

Journal
Hong Kong Journal of Emergency Medicine
Published
2024-11-19
DOI
https://doi.org/10.1002/hkj2.12054
Citations
1
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The use of point‐of‐care ultrasound for detection of retinal detachment in emergency department

Kim Woo Sung, Kin Chiu, Ping Chung Gordon Lee, Ho Yin Edwin Chan et al.
1 citations
Hong Kong Journal of Emergency Medicine
Ultrasound in Clinical Applications
0.42
article

The use of point‐of‐care ultrasound for detection of retinal detachment in emergency department

Kim Woo Sung, Kin Chiu, Ping Chung Gordon Lee, Ho Yin Edwin Chan, Chi Li
article en
1 citations

Abstract

Abstract Introduction Retinal detachment (RD) is an ocular emergency commonly encountered in the emergency department (ED). Point‐of‐care ultrasound (POCUS) has been proposed to rapidly identify the diagnosis. This study aimed to assess the accuracy of POCUS for detection of RD by a group of emergency physicians (EP) who had no prior experience in ocular POCUS. Methods This was a retrospective single‐center cohort study conducted between July 2023 and April 2024. All EP without any experience of POCUS in the department were invited to participate voluntarily in the study. They received a structured training session prior to the commencement of study which included a 30‐min lecture followed by a 30‐min supervised hands‐on practice on healthy individuals. All adult patients presenting to ED with acute onset flashes, floaters, and monocular visual loss were included. Patients who met one of the following criteria were excluded: pre‐existing or known RD, suspected ruptured eyeball, and unable to communicate in either Chinese or English. The final diagnosis by ophthalmologists were used as the gold standard for comparison. Results A total of 12 EP participated in the study and 89 patients were identified. Fourteen of them received the diagnosis of RD by ophthalmologists. Overall, the sensitivity of ocular POCUS was 93% (95% confidence interval (CI = 66%–100%). Specificity was 89% (95% CI = 80%–95%). The positive predictive value was 62% (95% CI = 45%–76%) and the negative predictive value was 98% (95% CI = 91%–100%). Conclusion Ocular POCUS has high sensitivity and negative predictive value for detection of RD. It is a useful and readily available diagnostic tool in ED even for EP without prior experience.

Hong Kong Journal of Emergency MedicineVol. 31(6)
Caritas Medical Centre (CN)
Openalex Percentile: Top 33%
Ultrasound in Clinical Applications
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The use of point‐of‐care ultrasound for detection of retinal detachment in emergency department — Kim Woo Sung, Kin Chiu, et al. · Hong Kong Journal of Emergency Medicine (2024) | TGRS Research Map | TGRS