Novel biocompatible magnetron-sputtered silver coating for enhanced antibacterial properties and osteogenesis in vitro

Peri-implant infection is a serious complication in orthopedic surgery. This study aimed to reduce the incidence of peri-implant infection by developing a durable and safe antibacterial silver coating. We compared the antibacterial properties and process controllability of various coating techniques to identify the most effective method for silver coating. We refined substrate treatment techniques and coating thicknesses through antibacterial and scratch tests. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to analyze the coating's morphology and composition. Micron-sized magnetron sputtering silver coating samples underwent in vitro antibacterial testing, cytotoxicity testing, silver ion release testing, and osteogenic testing using membrane contact culture, CCK-8 assay, inductively coupled plasma (ICP) detection, and alkaline phosphatase (ALP) activity/osteogenic gene PCR. Magnetron sputtering demonstrated superior antibacterial properties, uniformity, and process controllability compared to alternative techniques. The optimal adhesion strength was achieved with a 0.5 μm coating thickness and a 400 mesh sandpaper pretreatment process, without compromising antibacterial efficacy. The coating showed near-perfect antiseptic results in antibacterial and anti-biofilm tests. Fibroblasts cultured in silver ion precipitation medium exhibited growth rates of 89% on day 30 and 88% on day 90, compared to 95% in the control group. The osteogenic test indicated that the magnetron sputtering silver coating promotes osteogenesis effectively. Our study demonstrated that micron-sized magnetron sputtering silver coating has potential for clinical use to prevent peri-implant infections in the future.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-19
DOI
https://doi.org/10.1038/s41598-024-77270-4
Citations
3
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel biocompatible magnetron-sputtered silver coating for enhanced antibacterial properties and osteogenesis in vitro

Wenjuan Rong, Talante Juma, Bingxiao Yu, Hua Tian et al.
3 citations
Scientific Reports
Orthopedic Infections and Treatments
1.72
article

Novel biocompatible magnetron-sputtered silver coating for enhanced antibacterial properties and osteogenesis in vitro

Wenjuan Rong, Talante Juma, Bingxiao Yu, Hua Tian, Yongping Cao, Xiangyu Cao, Hongbin Wang, Hao Wang, Qiwei Wang, Xiaotong Bao
article en
3 citations

Abstract

Peri-implant infection is a serious complication in orthopedic surgery. This study aimed to reduce the incidence of peri-implant infection by developing a durable and safe antibacterial silver coating. We compared the antibacterial properties and process controllability of various coating techniques to identify the most effective method for silver coating. We refined substrate treatment techniques and coating thicknesses through antibacterial and scratch tests. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to analyze the coating's morphology and composition. Micron-sized magnetron sputtering silver coating samples underwent in vitro antibacterial testing, cytotoxicity testing, silver ion release testing, and osteogenic testing using membrane contact culture, CCK-8 assay, inductively coupled plasma (ICP) detection, and alkaline phosphatase (ALP) activity/osteogenic gene PCR. Magnetron sputtering demonstrated superior antibacterial properties, uniformity, and process controllability compared to alternative techniques. The optimal adhesion strength was achieved with a 0.5 μm coating thickness and a 400 mesh sandpaper pretreatment process, without compromising antibacterial efficacy. The coating showed near-perfect antiseptic results in antibacterial and anti-biofilm tests. Fibroblasts cultured in silver ion precipitation medium exhibited growth rates of 89% on day 30 and 88% on day 90, compared to 95% in the control group. The osteogenic test indicated that the magnetron sputtering silver coating promotes osteogenesis effectively. Our study demonstrated that micron-sized magnetron sputtering silver coating has potential for clinical use to prevent peri-implant infections in the future.

Scientific ReportsVol. 14(1)
China Aerospace Science and Industry Corporation (China) (CN), Peking University (CN), Peking University First Hospital (CN), Peking University Shougang Hospital (CN), Peking University Third Hospital (CN), Environmental Protection Research Institute of Light Industry (CN)
Peking University First Hospital, Government of Jiangsu Province, Peking University, Science and Technology Support Program of Jiangsu Province, Beijing Science and Technology Planning Project
Openalex Percentile: Top 14%
Orthopedic Infections and Treatments
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.