Accelerated Life Tests for Time-Dependent Response Characterization of Functionalized Piezoelectric Microcantilever-Based Gas Sensors

This article explores the accelerated lifetime test approach to characterize the time-dependent response of a piezoelectrically driven microcantilever (PD-MC) based gas sensor. The novelty here relies on demonstrating how accelerated lifetime tests can be useful to differentiate sensing mechanisms for non-linear gas sensors. The results show the determination of the sensor’s optimum operation time while maintaining result validity. The approach is demonstrated for 1,5-diaminopentane (cadaverine), a volatile organic compound (VOC) whose concentration in meat and fish products has been proven viable for determining the shelf life. A PD-MC functionalized with a cadaverine-specific binder was therefore incorporated into a hand-held electronic nose, and the response was found to be highly reliable within a specific resonance frequency shift, enabling the accurate prediction of meat and fish expiration dates. To identify the limits of detection in terms of cadaverine concentration and sensor lifetime, this study applies the results of accelerated life tests into a Weibull distribution analysis to extract the expected time to failure. For the accelerated life tests, a functionalized PD-MC was exposed to high concentrations of cadaverine, i.e., 252.3 mg/kg, 335.82 mg/kg, and 421.08 mg/kg, compared to the nominal concentration of 33 mg/kg observed in meat and fish samples. Furthermore, we demonstrate the differentiation of the response mechanisms of the system accruing from the concentration-dependent interaction of cadaverine with the binder. This enables the determination of the upper limit of the analyte concentration for a stable response. The findings suggest that the functionalized PD-MC sensor exhibits a linear and predictable response when exposed to a standard cadaverine concentration of 33 mg/kg for up to 93.01 min.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-11-18
DOI
https://doi.org/10.3390/electronics13224525
Citations
2
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accelerated Life Tests for Time-Dependent Response Characterization of Functionalized Piezoelectric Microcantilever-Based Gas Sensors

Roana de Oliveira Hansen, Lawrence Nsubuga
2 citations
Electronics
Mechanical and Optical Resonators
0.68
article

Accelerated Life Tests for Time-Dependent Response Characterization of Functionalized Piezoelectric Microcantilever-Based Gas Sensors

Roana de Oliveira Hansen, Lawrence Nsubuga
article en
2 citations

Abstract

This article explores the accelerated lifetime test approach to characterize the time-dependent response of a piezoelectrically driven microcantilever (PD-MC) based gas sensor. The novelty here relies on demonstrating how accelerated lifetime tests can be useful to differentiate sensing mechanisms for non-linear gas sensors. The results show the determination of the sensor’s optimum operation time while maintaining result validity. The approach is demonstrated for 1,5-diaminopentane (cadaverine), a volatile organic compound (VOC) whose concentration in meat and fish products has been proven viable for determining the shelf life. A PD-MC functionalized with a cadaverine-specific binder was therefore incorporated into a hand-held electronic nose, and the response was found to be highly reliable within a specific resonance frequency shift, enabling the accurate prediction of meat and fish expiration dates. To identify the limits of detection in terms of cadaverine concentration and sensor lifetime, this study applies the results of accelerated life tests into a Weibull distribution analysis to extract the expected time to failure. For the accelerated life tests, a functionalized PD-MC was exposed to high concentrations of cadaverine, i.e., 252.3 mg/kg, 335.82 mg/kg, and 421.08 mg/kg, compared to the nominal concentration of 33 mg/kg observed in meat and fish samples. Furthermore, we demonstrate the differentiation of the response mechanisms of the system accruing from the concentration-dependent interaction of cadaverine with the binder. This enables the determination of the upper limit of the analyte concentration for a stable response. The findings suggest that the functionalized PD-MC sensor exhibits a linear and predictable response when exposed to a standard cadaverine concentration of 33 mg/kg for up to 93.01 min.

ElectronicsVol. 13(22)
University of Southern Denmark (DK)
European Regional Development Fund, Interreg
Life below water
Openalex Percentile: Top 30%
Mechanical and Optical Resonators
0.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accelerated Life Tests for Time-Dependent Response Characterization of Functionalized Piezoelectric Microcantilever-Based Gas Sensors — Roana de Oliveira Hansen, Lawrence Nsubuga · Electronics (2024) | TGRS Research Map | TGRS