Simultaneous determination of nineteen azo dyes in water samples by gas chromatography-mass spectrometry after Fe3O4@COF based dispersive solid phase extraction

This study was performed for the determination of nineteen azo dyes at trace levels in stream water sample by gas chromatography-mass spectrometry (GC-MS). The selected analytes were preconcentrated with the help of dispersive solid phase extraction (DSPE). Fe<sub>3</sub>O<sub>4</sub> magnetic nanoparticle was modified with covalent organic framework (COF) and the synthesized Fe<sub>3</sub>O<sub>4</sub>@COF nanocomposite was used as adsorbent for the separation of the analytes from aqueous solution. The synthesized Fe<sub>3</sub>O<sub>4</sub>@COF was introduced to the literature for the first time in this study. Five different parameters (pH, volume of buffer solution, volume of desorption solvent, mixing period and amount of adsorbent) were univariately optimized to acquire high extraction outputs for each analyte. Under the optimum Fe<sub>3</sub>O<sub>4</sub>@COF-DSPE-GC-MS conditions, limit of detection (LOD), limit of quantitation (LOQ), linear range (LR), coefficient of determination (R<sup>2</sup>) and percent relative standard deviation (%RSD) were calculated using external calibration plots belonging to each analyte. LOD values were found between 2.8 and 70.7 μg/kg with corresponding LOQ values ranging between 9.5 and 235.7 μg/kg. In addition, %RSD values were lower than 12.8%. Matrix matching calibration method was used in spiking experiments. Percent recovery results obtained for spiked stream water samples were between 83.1 and 122.4%, with %RSD ≤ 17.5. The high percent recoveries confirmed the accuracy and applicability of the developed Fe<sub>3</sub>O<sub>4</sub>@COF-DSPE-GC-MS method for stream water samples.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-18
DOI
https://doi.org/10.1038/s41598-024-80097-8
Citations
2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous determination of nineteen azo dyes in water samples by gas chromatography-mass spectrometry after Fe3O4@COF based dispersive solid phase extraction

Ömer Tahir Günkara, Sezgin Bakırdere, Sezin Erarpat, Nazime Ebrar Karlıdağ
2 citations
Scientific Reports
Analytical chemistry methods development
0.47
article

Simultaneous determination of nineteen azo dyes in water samples by gas chromatography-mass spectrometry after Fe3O4@COF based dispersive solid phase extraction

Ömer Tahir Günkara, Sezgin Bakırdere, Sezin Erarpat, Nazime Ebrar Karlıdağ
article en
2 citations

Abstract

This study was performed for the determination of nineteen azo dyes at trace levels in stream water sample by gas chromatography-mass spectrometry (GC-MS). The selected analytes were preconcentrated with the help of dispersive solid phase extraction (DSPE). Fe<sub>3</sub>O<sub>4</sub> magnetic nanoparticle was modified with covalent organic framework (COF) and the synthesized Fe<sub>3</sub>O<sub>4</sub>@COF nanocomposite was used as adsorbent for the separation of the analytes from aqueous solution. The synthesized Fe<sub>3</sub>O<sub>4</sub>@COF was introduced to the literature for the first time in this study. Five different parameters (pH, volume of buffer solution, volume of desorption solvent, mixing period and amount of adsorbent) were univariately optimized to acquire high extraction outputs for each analyte. Under the optimum Fe<sub>3</sub>O<sub>4</sub>@COF-DSPE-GC-MS conditions, limit of detection (LOD), limit of quantitation (LOQ), linear range (LR), coefficient of determination (R<sup>2</sup>) and percent relative standard deviation (%RSD) were calculated using external calibration plots belonging to each analyte. LOD values were found between 2.8 and 70.7 μg/kg with corresponding LOQ values ranging between 9.5 and 235.7 μg/kg. In addition, %RSD values were lower than 12.8%. Matrix matching calibration method was used in spiking experiments. Percent recovery results obtained for spiked stream water samples were between 83.1 and 122.4%, with %RSD ≤ 17.5. The high percent recoveries confirmed the accuracy and applicability of the developed Fe<sub>3</sub>O<sub>4</sub>@COF-DSPE-GC-MS method for stream water samples.

Scientific ReportsVol. 14(1)
Yıldız Technical University (TR), Istanbul Technical University (TR)
Clean water and sanitation
Openalex Percentile: Top 40%
Analytical chemistry methods development
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.