Negative-sequence current filter based on inductance coils

The construction of new relay protection systems without the use of current transformers is a fundamental problem of electro energetics, which has not yet been solved. This works suggests a negative-sequence current filter which receives information from inductance coils (ICs) mounted at a safe distance in the magnetic field of phase currents. This filter does not require current transformers, thus saving high-quality copper, steel, and expensive high-voltage insulation in amount unprecedented for relay protection (a 6 to 110 kV current transformer has 19 to 480 kg in weight). A circuit (including functional diagnostics) and a technique for selecting the parameters of filter components and the points where ICs should be fixed are presented; a structure for IC fastening is described. Computer simulation and experiment were used for data collection. The data show that i) the filter conversion coefficient m= 1.6, and imbalance increases by 7% at the network frequency f= 48–52 Hz; ii) protections based on this filter should have a time delay; iii) the filter is not inferior to well-known well-tested filters with current transformers; and iv) it is functional, but can only be used for single-standing electrical installations.

Authors

Institutions

Publication Details

Journal
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Published
2024-11-18
DOI
https://doi.org/10.11591/ijece.v15i1.pp24-35
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Negative-sequence current filter based on inductance coils

Rizagul Mashrapova, Bauyrzhan Mashrapov, А. П. Кислов, Mark Kletsel
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Non-Destructive Testing Techniques
article

Negative-sequence current filter based on inductance coils

Rizagul Mashrapova, Bauyrzhan Mashrapov, А. П. Кислов, Mark Kletsel
article en

Abstract

The construction of new relay protection systems without the use of current transformers is a fundamental problem of electro energetics, which has not yet been solved. This works suggests a negative-sequence current filter which receives information from inductance coils (ICs) mounted at a safe distance in the magnetic field of phase currents. This filter does not require current transformers, thus saving high-quality copper, steel, and expensive high-voltage insulation in amount unprecedented for relay protection (a 6 to 110 kV current transformer has 19 to 480 kg in weight). A circuit (including functional diagnostics) and a technique for selecting the parameters of filter components and the points where ICs should be fixed are presented; a structure for IC fastening is described. Computer simulation and experiment were used for data collection. The data show that i) the filter conversion coefficient m= 1.6, and imbalance increases by 7% at the network frequency f= 48–52 Hz; ii) protections based on this filter should have a time delay; iii) the filter is not inferior to well-known well-tested filters with current transformers; and iv) it is functional, but can only be used for single-standing electrical installations.

International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer EngineeringVol. 15(1)
Toraighyrov University (KZ)
Affordable and clean energy
Openalex Percentile: Top 79%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.