Enhancing the reliance of emergency power supply systems for nuclear facilities using hybrid system

The performance of an atomic facility depends on the efficient supply of electricity, particularly emergency loads like monitoring and control equipment, radiation safety systems, and emergency lights. Most nuclear facilities rely on diesel generators to supply emergency loads during grid outages. Due to the diesel generator's imperfections, such as its starting time, it may fail to deliver power because it is unavailable due to maintenance, failure to start, or failure to run and supply the load. It cannot immediately supply the critical loads, resulting in a blackout and the release of radioactive substances into the environment. To address the previous issues, this paper proposes an improved method to enhance the reliability of nuclear facilities for providing electricity to safety and critical consumers during normal and emergency operating modes. The approach incorporates a photovoltaic (PV) system/battery, and its robustness and performance are tested using load flow and transient stability analysis. The simulation results demonstrated the effectiveness and speed of the proposed method when compared to the traditional method, as the emergency consumers were successfully powered within a very short time without fluctuations, and the voltage reduction and frequency were within the nominal values. The electrical transient analyzer program (ETAP) is used to validate these results.

Authors

Institutions

Publication Details

Journal
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Published
2024-11-18
DOI
https://doi.org/10.11591/ijece.v15i1.pp36-45
Citations
1
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the reliance of emergency power supply systems for nuclear facilities using hybrid system

Hussein El-Eissawi, Mohammed Saade, Adel S. Nada
1 citations
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Advanced Battery Technologies Research
0.20
article

Enhancing the reliance of emergency power supply systems for nuclear facilities using hybrid system

Hussein El-Eissawi, Mohammed Saade, Adel S. Nada
article en
1 citations

Abstract

The performance of an atomic facility depends on the efficient supply of electricity, particularly emergency loads like monitoring and control equipment, radiation safety systems, and emergency lights. Most nuclear facilities rely on diesel generators to supply emergency loads during grid outages. Due to the diesel generator's imperfections, such as its starting time, it may fail to deliver power because it is unavailable due to maintenance, failure to start, or failure to run and supply the load. It cannot immediately supply the critical loads, resulting in a blackout and the release of radioactive substances into the environment. To address the previous issues, this paper proposes an improved method to enhance the reliability of nuclear facilities for providing electricity to safety and critical consumers during normal and emergency operating modes. The approach incorporates a photovoltaic (PV) system/battery, and its robustness and performance are tested using load flow and transient stability analysis. The simulation results demonstrated the effectiveness and speed of the proposed method when compared to the traditional method, as the emergency consumers were successfully powered within a very short time without fluctuations, and the voltage reduction and frequency were within the nominal values. The electrical transient analyzer program (ETAP) is used to validate these results.

International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer EngineeringVol. 15(1)
Egyptian Atomic Energy Authority (EG), Nuclear Materials Authority (EG), Al-Azhar University (ID), Egyptian Government (EG)
Affordable and clean energy
Openalex Percentile: Top 48%
Advanced Battery Technologies Research
0.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing the reliance of emergency power supply systems for nuclear facilities using hybrid system — Hussein El-Eissawi, Mohammed Saade, et al. · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering (2024) | TGRS Research Map | TGRS