Numerical analysis and experimental study of two-phase flow pattern and pressure drop characteristics in internally microfin tubes

Microfin tubes with internal structures exhibit superior thermo-hydraulic performance, making them indispensable in systems such as air conditioning, chemical industry, and heat pumps. Despite their widespread application, research on microfin tubes has predominantly concentrated on single-phase flows. The heat transfer coefficient of phase change heat transfer is much higher than that of single-phase heat transfer. The higher heat transfer coefficient enables micro finned tubes using phase change heat transfer to significantly improve heat transfer efficiency while reducing equipment size. The understanding of gas-liquid two-phase flow characteristics is crucial for heat and mass transfer rates and pressure drop. This study examines the two-phase flow patterns and pressure drop characteristics within microfin tubes, considering variables such as two-phase Reynolds number (200≤Re ≤ 600), gas void fraction (0.3≤ ζ ≤ 0.55), tube inner diameter (2.5≤ d ≤ 5 mm), helix angle (0°≤ β ≤ 36°), and microfin count (20≤ N s ≤ 60) through both experimental and numerical approaches. The findings reveal that the inlet Reynolds number and microfin count exert negligible effects on bubble dimensions and morphology. As the gas void fraction and helix angle increase, the gas-liquid interfacial profiles become more symmetric. The influence of changes in bubble length and gas void fraction on bubble velocity can be ignored. When the helix angle is 18°, friction resistance factor in the liquid column region is the minimum of 0.04. The friction resistance factor in the liquid column region decreases with the increase of two-phase Reynolds number and microfin count, and decreases with the decrease of gas void fraction and tube inner diameter.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-11-18
DOI
https://doi.org/10.1016/j.csite.2024.105521
Citations
6
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical analysis and experimental study of two-phase flow pattern and pressure drop characteristics in internally microfin tubes

Jingzhi Zhang, Bangming Li, Naixiang Zhou, Bo Zhang et al.
6 citations
Case Studies in Thermal Engineering
Heat Transfer and Boiling Studies
1.28
article

Numerical analysis and experimental study of two-phase flow pattern and pressure drop characteristics in internally microfin tubes

Jingzhi Zhang, Bangming Li, Naixiang Zhou, Bo Zhang, Liangliang Zhang, Lei Li
article en
6 citations

Abstract

Microfin tubes with internal structures exhibit superior thermo-hydraulic performance, making them indispensable in systems such as air conditioning, chemical industry, and heat pumps. Despite their widespread application, research on microfin tubes has predominantly concentrated on single-phase flows. The heat transfer coefficient of phase change heat transfer is much higher than that of single-phase heat transfer. The higher heat transfer coefficient enables micro finned tubes using phase change heat transfer to significantly improve heat transfer efficiency while reducing equipment size. The understanding of gas-liquid two-phase flow characteristics is crucial for heat and mass transfer rates and pressure drop. This study examines the two-phase flow patterns and pressure drop characteristics within microfin tubes, considering variables such as two-phase Reynolds number (200≤Re ≤ 600), gas void fraction (0.3≤ ζ ≤ 0.55), tube inner diameter (2.5≤ d ≤ 5 mm), helix angle (0°≤ β ≤ 36°), and microfin count (20≤ N s ≤ 60) through both experimental and numerical approaches. The findings reveal that the inlet Reynolds number and microfin count exert negligible effects on bubble dimensions and morphology. As the gas void fraction and helix angle increase, the gas-liquid interfacial profiles become more symmetric. The influence of changes in bubble length and gas void fraction on bubble velocity can be ignored. When the helix angle is 18°, friction resistance factor in the liquid column region is the minimum of 0.04. The friction resistance factor in the liquid column region decreases with the increase of two-phase Reynolds number and microfin count, and decreases with the decrease of gas void fraction and tube inner diameter.

Case Studies in Thermal EngineeringVol. 64
Shandong University (CN), Wuhan Ship Development & Design Institute (CN)
Openalex Percentile: Top 22%
Heat Transfer and Boiling Studies
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.