Graphitized carbon encapsulated Co anode electrochemically activating persulfate for sulfamethoxazole degradation

The excessive use of antibiotics like sulfamethoxazole (SMX) is causing environmental pollution and endangering human health and the ecosystem. Using transition metals as catalysts to activate persulfate (PS) can effectively degrade the organic pollutants in the advanced oxidation process (AOP). However, the high dissolution of the transition metals leads to poor stability, low efficiency in pollutant degradation, and secondary pollution. In this work, a graphitized carbon encapsulated Co (Co@EC) anode is developed for electrochemically activating peroxymonosulfate (PMS) to degrade SMX. It is found that the synergistic effect of Co@EC, PMS, and current significantly enhances SMX degradation. Under optimal conditions (current density of 5 mA cm −2 , pH of 9, and PMS concentration of 0.25 mM), the Co@EC anode can completely remove 10 μM of SMX in 9 min, a much higher efficiency compared to processes without PMS, Co, or current. The rapid reaction kinetics (6.69×10 −1 min −1 ) at optimal conditions are associated with the two main active species of 1 O 2 and O 2 • − during electroactivation. Furthermore, the Co@EC anode maintains high degradation efficiency and low dissolution after repeated cycling tests due to its structural stability . These findings provide new insights and strategies for developing stable catalysts. • A graphitized carbon encapsulated Co anode (Co@EC) material is prepared by MSCC-ET technology. • This anode can electrochemically activate PMS to fast degrade SMX within 9 min under optimal conditions. • The exists a synergistic effect between Co@EC, PMS, and current. • 1 O 2 and O 2 •- are the two main active species during electroactivation of PMS. • This anode exhibits good structural stability.

Authors

Institutions

Publication Details

Journal
Journal of environmental chemical engineering
Published
2024-11-18
DOI
https://doi.org/10.1016/j.jece.2024.114847
Citations
9
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
1.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Graphitized carbon encapsulated Co anode electrochemically activating persulfate for sulfamethoxazole degradation

Dihua Wang, Zhaoyi Han, Wentao Qiu, Hao Shan Shi et al.
9 citations
Journal of environmental chemical engineering
Advanced oxidation water treatment
1.81
article

Graphitized carbon encapsulated Co anode electrochemically activating persulfate for sulfamethoxazole degradation

Dihua Wang, Zhaoyi Han, Wentao Qiu, Hao Shan Shi, Dongdong Zhu, Wei Li
article en
9 citations

Abstract

The excessive use of antibiotics like sulfamethoxazole (SMX) is causing environmental pollution and endangering human health and the ecosystem. Using transition metals as catalysts to activate persulfate (PS) can effectively degrade the organic pollutants in the advanced oxidation process (AOP). However, the high dissolution of the transition metals leads to poor stability, low efficiency in pollutant degradation, and secondary pollution. In this work, a graphitized carbon encapsulated Co (Co@EC) anode is developed for electrochemically activating peroxymonosulfate (PMS) to degrade SMX. It is found that the synergistic effect of Co@EC, PMS, and current significantly enhances SMX degradation. Under optimal conditions (current density of 5 mA cm −2 , pH of 9, and PMS concentration of 0.25 mM), the Co@EC anode can completely remove 10 μM of SMX in 9 min, a much higher efficiency compared to processes without PMS, Co, or current. The rapid reaction kinetics (6.69×10 −1 min −1 ) at optimal conditions are associated with the two main active species of 1 O 2 and O 2 • − during electroactivation. Furthermore, the Co@EC anode maintains high degradation efficiency and low dissolution after repeated cycling tests due to its structural stability . These findings provide new insights and strategies for developing stable catalysts. • A graphitized carbon encapsulated Co anode (Co@EC) material is prepared by MSCC-ET technology. • This anode can electrochemically activate PMS to fast degrade SMX within 9 min under optimal conditions. • The exists a synergistic effect between Co@EC, PMS, and current. • 1 O 2 and O 2 •- are the two main active species during electroactivation of PMS. • This anode exhibits good structural stability.

Journal of environmental chemical engineeringVol. 12(6)
Wuhan University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hubei Province
Openalex Percentile: Top 16%
Advanced oxidation water treatment
1.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.