A High-Precision Roundness Error Separation Method Based on Time–Frequency-Domain Transformation for Parameter Optimization

The high-precision metrological measurement of circular profile is crucial for various rotational parts, essential in precision machining, manufacturing, and assembly. The existing roundness error separation methods often suffer from harmonic suppression issues, limiting the range of separable harmonics and reducing accuracy. This article proposes a roundness error separation method based on time-frequency-domain transformation (TFDT) for parameter optimization to overcome these challenges. By establishing the relationship between separation accuracy and rotation angle error and optimizing parameters accordingly, the method balances error separation accuracy with the separable harmonic range. Theoretical simulations and experimental validations confirm the method’s effectiveness. By comparing the separation results under different harmonic separation range requirements with those of the methods currently widely used in the field of roundness metrology, we have validated the effectiveness of this method in balancing separation range and accuracy. When the rotation angle is set to 1.406°, the harmonic suppression-free range expands from [0, 204] undulations per revolution (upr) to [0, 255] upr, representing an increase of approximately 25% compared to single-step rotation error separation technique (SEST). Compared to the SEST method, the deviation of this method from the multistep method is reduced by over 68%, and its standard deviation (STD) is only about 65% of that of the other two methods. This innovative approach provides comprehensive and accurate circular profile data, enabling high-precision roundness error separation across a broad harmonic range. It establishes a robust theoretical basis for advanced measurements in national metrology institutes and key laboratories.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2024-11-18
DOI
https://doi.org/10.1109/tim.2024.3500056
Citations
7
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
1.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Precision Roundness Error Separation Method Based on Time–Frequency-Domain Transformation for Parameter Optimization

Chunyu Shao, Yongmeng Liu, Jiubin Tan, Ruirui Li et al.
7 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Measurement and Metrology Techniques
1.49
article

A High-Precision Roundness Error Separation Method Based on Time–Frequency-Domain Transformation for Parameter Optimization

Chunyu Shao, Yongmeng Liu, Jiubin Tan, Ruirui Li, Chuanzhi Sun
article en
7 citations

Abstract

The high-precision metrological measurement of circular profile is crucial for various rotational parts, essential in precision machining, manufacturing, and assembly. The existing roundness error separation methods often suffer from harmonic suppression issues, limiting the range of separable harmonics and reducing accuracy. This article proposes a roundness error separation method based on time-frequency-domain transformation (TFDT) for parameter optimization to overcome these challenges. By establishing the relationship between separation accuracy and rotation angle error and optimizing parameters accordingly, the method balances error separation accuracy with the separable harmonic range. Theoretical simulations and experimental validations confirm the method’s effectiveness. By comparing the separation results under different harmonic separation range requirements with those of the methods currently widely used in the field of roundness metrology, we have validated the effectiveness of this method in balancing separation range and accuracy. When the rotation angle is set to 1.406°, the harmonic suppression-free range expands from [0, 204] undulations per revolution (upr) to [0, 255] upr, representing an increase of approximately 25% compared to single-step rotation error separation technique (SEST). Compared to the SEST method, the deviation of this method from the multistep method is reduced by over 68%, and its standard deviation (STD) is only about 65% of that of the other two methods. This innovative approach provides comprehensive and accurate circular profile data, enabling high-precision roundness error separation across a broad harmonic range. It establishes a robust theoretical basis for advanced measurements in national metrology institutes and key laboratories.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Harbin Institute of Technology (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 19%
Advanced Measurement and Metrology Techniques
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.