X-ray dose rate detection sensor based on GAGG: Ce RL and fiber optic transmission

No report has been made on the properties of radiation dose rate detection using GAGG: Ce scintillator radioluminescence (RL). This report reveals for the first time the properties of GAGG: Ce scintillators combined with photomultiplier tubes (PMTs) as detectors using optical fibers. We have thoroughly investigated the detection performance of two different sizes of GAGG: Ce scintillators. The experimental results show that the combination of the RL signal of the GAGG: Ce scintillator with the PMT signal can be used to accurately measure the dose rate during irradiation. At a constant dose rate of 10 μsv/h, the stability of the count rate during irradiation was kept within 5%. Meanwhile, the deviation of the count rate was also controlled within 5% at different radiation dose rates. The detector exhibits excellent linear response (R2=0.9910 and R2=0.9807) over the dose rate range of 20 μsv/h to 100 μsv/h. This radiation detector based on GAGG: Ce scintillator and optical fiber transmission is expected to be valuable for a wide range of applications in the fields of radiation monitoring, safety and security, and medical diagnostics, thanks to its compact design, high stability detection capability and real-time measurement function.

Authors

Institutions

Publication Details

Published
2024-11-18
DOI
https://doi.org/10.1117/12.3054471
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-ray dose rate detection sensor based on GAGG: Ce RL and fiber optic transmission

Hongxiang Kang, Qingyu Cai, Xiaoan Tang, C.C. Wang et al.
1 citations
Radiation Detection and Scintillator Technologies
0.61
article

X-ray dose rate detection sensor based on GAGG: Ce RL and fiber optic transmission

Hongxiang Kang, Qingyu Cai, Xiaoan Tang, C.C. Wang, Qiong Ma, Haiyang Sun, Nan Yu
article en
1 citations

Abstract

No report has been made on the properties of radiation dose rate detection using GAGG: Ce scintillator radioluminescence (RL). This report reveals for the first time the properties of GAGG: Ce scintillators combined with photomultiplier tubes (PMTs) as detectors using optical fibers. We have thoroughly investigated the detection performance of two different sizes of GAGG: Ce scintillators. The experimental results show that the combination of the RL signal of the GAGG: Ce scintillator with the PMT signal can be used to accurately measure the dose rate during irradiation. At a constant dose rate of 10 μsv/h, the stability of the count rate during irradiation was kept within 5%. Meanwhile, the deviation of the count rate was also controlled within 5% at different radiation dose rates. The detector exhibits excellent linear response (R2=0.9910 and R2=0.9807) over the dose rate range of 20 μsv/h to 100 μsv/h. This radiation detector based on GAGG: Ce scintillator and optical fiber transmission is expected to be valuable for a wide range of applications in the fields of radiation monitoring, safety and security, and medical diagnostics, thanks to its compact design, high stability detection capability and real-time measurement function.

Henan University of Science and Technology (CN), Sany (China) (CN), Beijing Radiation Center (CN)
Affordable and clean energy
Openalex Percentile: Top 29%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.