Development of a Shoelace Tensile Testing System and Investigation into the Effects of Different Running Speeds on Shoelace Tensile Variation

Abstract This study investigated the validity and sensitivity of a custom-made shoelace tensile testing system. The aim was to analyze the distribution pattern of shoelace tension in different positions and under different tightness levels during running. Mechanical tests were conducted using 16 weights, and various statistical analyses, including linear regression, Bland-Altman plots, coefficient of variation, and intraclass correlation coefficient, were performed to assess the system’s validity. Fifteen male amateur runners participated in the study, and three conditions (loose, comfortable, and tight) were measured during an upright stance. The system utilized VICON motion systems, a Kistler force plate, and a Photoelectric gate speed measurement system. Results showed a linear relationship between voltage and load at the three sensors (R2 ≥ 0.9997). Bland-Altman plots demonstrated 95% prediction intervals within ± 1.96SD from zero for all sensors. The average coefficient of variation for each sensor was less than 0.38%. Intraclass correlation coefficient values were larger than 0.999 ( p <0.0001) for each sensor. The peak tension of the front shoelace was greater than that of the front and middle when the shoelace was loose and tight. The rear shoelace had the highest tension force. The study also found that shoelace tension varied throughout the gait cycle during running. Overall, this research provides a novel and validated method for measuring shoelace tensile stress, which has implications for developing automatic shoelace fastening systems.

Authors

Institutions

Publication Details

Journal
Journal of Bionic Engineering
Published
2024-11-18
DOI
https://doi.org/10.1007/s42235-024-00612-5
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Shoelace Tensile Testing System and Investigation into the Effects of Different Running Speeds on Shoelace Tensile Variation

Biao Yan, Jiahao Pan, Shutao Wei, Xinyu Guo et al.
Journal of Bionic Engineering
Lower Extremity Biomechanics and Pathologies
article

Development of a Shoelace Tensile Testing System and Investigation into the Effects of Different Running Speeds on Shoelace Tensile Variation

Biao Yan, Jiahao Pan, Shutao Wei, Xinyu Guo, Shaocong Zhao, Li Li Li, Lingjun Li
article en

Abstract

Abstract This study investigated the validity and sensitivity of a custom-made shoelace tensile testing system. The aim was to analyze the distribution pattern of shoelace tension in different positions and under different tightness levels during running. Mechanical tests were conducted using 16 weights, and various statistical analyses, including linear regression, Bland-Altman plots, coefficient of variation, and intraclass correlation coefficient, were performed to assess the system’s validity. Fifteen male amateur runners participated in the study, and three conditions (loose, comfortable, and tight) were measured during an upright stance. The system utilized VICON motion systems, a Kistler force plate, and a Photoelectric gate speed measurement system. Results showed a linear relationship between voltage and load at the three sensors (R2 ≥ 0.9997). Bland-Altman plots demonstrated 95% prediction intervals within ± 1.96SD from zero for all sensors. The average coefficient of variation for each sensor was less than 0.38%. Intraclass correlation coefficient values were larger than 0.999 ( p <0.0001) for each sensor. The peak tension of the front shoelace was greater than that of the front and middle when the shoelace was loose and tight. The rear shoelace had the highest tension force. The study also found that shoelace tension varied throughout the gait cycle during running. Overall, this research provides a novel and validated method for measuring shoelace tensile stress, which has implications for developing automatic shoelace fastening systems.

Journal of Bionic EngineeringVol. 22(1)
Boise State University (US), Georgia Southern University (US), China Leather and Footwear Industry Research Institute (CN), Shaanxi University of Science and Technology (CN), Xiamen University of Technology (CN)
Openalex Percentile: Top 81%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.