Application and evaluation knitted electrodes for body signal measurement using adhesive intermediate electrode

Abstract Textile electrode is capable of measuring the myoelectric potentials of skeletal muscles such as electromyography (EMG), owing to their outstanding low weight, flexibility, breathability, and comfort properties. Nonetheless, textile surfaces often exhibit intermittent adhesion between the electrode surface and the skin, which can result in fluctuations in electrical resistivity due to the inherent characteristics of textiles. This study aimed to suggest the solutions to improve adhesive of textile electrode for the improvement of electrode performance with high quality signal by minimizing these intermittent contacts. For this, an adhesive intermediate, two different conductive materials, between the skin and the textile electrode was introduced to improve the instability skin contact, respectively. To assess the impact of various adhesive intermediates on knitted electrodes, two different types of adhesive intermediates were utilized: a conductive hydrogel-based adhesive intermediate and a conductive paste-based adhesive intermediate. Moreover, the durability of knitted electrodes with adhesive intermediate was evaluated by assessing the changes of signal quality during drying time for 180 min. As a results of sEMG measurement, it was confirmed that the sEMG signal was stably detecting by applying the adhesive intermediate. Both types of adhesive intermediate significantly increased the signal acquisition performance of knitted electrodes by more than threefold. After five washing cycle, the knitted electrodes with two types of adhesive intermediate maintained approximately 80% of their initial SNR values. Therefore, the use of the adhesive intermediate presented in this study not only improves the performance of the electrode but also ensures reusability.

Authors

Institutions

Publication Details

Journal
Fashion and Textiles
Published
2024-11-18
DOI
https://doi.org/10.1186/s40691-024-00404-9
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application and evaluation knitted electrodes for body signal measurement using adhesive intermediate electrode

Ji Eun Song, Sohee Lee
2 citations
Fashion and Textiles
Muscle activation and electromyography studies
0.37
article

Application and evaluation knitted electrodes for body signal measurement using adhesive intermediate electrode

Ji Eun Song, Sohee Lee
article en
2 citations

Abstract

Abstract Textile electrode is capable of measuring the myoelectric potentials of skeletal muscles such as electromyography (EMG), owing to their outstanding low weight, flexibility, breathability, and comfort properties. Nonetheless, textile surfaces often exhibit intermittent adhesion between the electrode surface and the skin, which can result in fluctuations in electrical resistivity due to the inherent characteristics of textiles. This study aimed to suggest the solutions to improve adhesive of textile electrode for the improvement of electrode performance with high quality signal by minimizing these intermittent contacts. For this, an adhesive intermediate, two different conductive materials, between the skin and the textile electrode was introduced to improve the instability skin contact, respectively. To assess the impact of various adhesive intermediates on knitted electrodes, two different types of adhesive intermediates were utilized: a conductive hydrogel-based adhesive intermediate and a conductive paste-based adhesive intermediate. Moreover, the durability of knitted electrodes with adhesive intermediate was evaluated by assessing the changes of signal quality during drying time for 180 min. As a results of sEMG measurement, it was confirmed that the sEMG signal was stably detecting by applying the adhesive intermediate. Both types of adhesive intermediate significantly increased the signal acquisition performance of knitted electrodes by more than threefold. After five washing cycle, the knitted electrodes with two types of adhesive intermediate maintained approximately 80% of their initial SNR values. Therefore, the use of the adhesive intermediate presented in this study not only improves the performance of the electrode but also ensures reusability.

Fashion and TextilesVol. 11(1)
Gyeongsang National University (KR), Seowon University (KR)
National Research Foundation of Korea
Openalex Percentile: Top 42%
Muscle activation and electromyography studies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.