Measurement of the Parameters of Selective Multiphoton Dissociation of 2-Chloroethenyl Dichloroborane Molecules by Pulsed CO2 Laser Radiation

The parameters of boron isotope-selective IR multiphoton (MP) dissociation of 2-chloroethenyl dichloroborane molecules (HClC=CHBCl2) under the action of pulsed CO2 laser radiation were measured. The laser radiation frequencies were tuned in resonance with the low-frequency wing of the IR absorption band of HClC=CH10BCl2 molecules. The dependences of the dissociation yields and selectivity of HClC=CH10BCl2 and HClC=CH11BCl2 molecules on the intrinsic gas pressure, laser radiation intensity and frequency, and N2 inert buffer gas and BCl3 resonance buffer gas pressures were obtained. At sufficiently high intrinsic pressures of HClC=CBCl2 (66.5−266 Pa) and moderate laser radiation intensity (2–3 J/cm2), high MP dissociation parameters are achieved: dissociation yields of HClC=CH10BCl2 molecules of up to 6–9% and selectivity from 30 to 100.

Authors

Institutions

Publication Details

Journal
Russian Journal of Physical Chemistry A
Published
2024-11-18
DOI
https://doi.org/10.1134/s0036024424702194
Citations
3
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of the Parameters of Selective Multiphoton Dissociation of 2-Chloroethenyl Dichloroborane Molecules by Pulsed CO2 Laser Radiation

E. A. Ryabov, S V Pigul'skiĭ, А. Н. Петин, Г. Н. Макаров et al.
3 citations
Russian Journal of Physical Chemistry A
Laser Design and Applications
0.63
article

Measurement of the Parameters of Selective Multiphoton Dissociation of 2-Chloroethenyl Dichloroborane Molecules by Pulsed CO2 Laser Radiation

E. A. Ryabov, S V Pigul'skiĭ, А. Н. Петин, Г. Н. Макаров, V. B. Laptev
article en
3 citations

Abstract

The parameters of boron isotope-selective IR multiphoton (MP) dissociation of 2-chloroethenyl dichloroborane molecules (HClC=CHBCl2) under the action of pulsed CO2 laser radiation were measured. The laser radiation frequencies were tuned in resonance with the low-frequency wing of the IR absorption band of HClC=CH10BCl2 molecules. The dependences of the dissociation yields and selectivity of HClC=CH10BCl2 and HClC=CH11BCl2 molecules on the intrinsic gas pressure, laser radiation intensity and frequency, and N2 inert buffer gas and BCl3 resonance buffer gas pressures were obtained. At sufficiently high intrinsic pressures of HClC=CBCl2 (66.5−266 Pa) and moderate laser radiation intensity (2–3 J/cm2), high MP dissociation parameters are achieved: dissociation yields of HClC=CH10BCl2 molecules of up to 6–9% and selectivity from 30 to 100.

Russian Journal of Physical Chemistry AVol. 98(12)
Institute of Spectroscopy (RU)
Openalex Percentile: Top 30%
Laser Design and Applications
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.