Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Humerothoracic Joint Angles Estimation

Calibrating inertial measurement units (IMUs) involves converting orientation data from a local reference frame into a clinically meaningful reference system. Several solutions exist but little work has been done to compare different calibration methods with each other and an optical motion capture system. Thirteen healthy subjects with no signs of upper limb injury were recruited for this study and instrumented with IMU sensors and optical markers. Three IMU calibration methods were compared: N-pose calibration, functional calibration, and manual alignment. Subjects executed simple single-plane single-joint tasks for each upper limb joint as well as more complex multijoint tasks. We performed a 3-way analysis of variance on range of motion error, root mean squared error, and offset to assess differences between calibrations, tasks, and anatomical axes. Differences in the 3 IMU calibrations are minor and not statistically significant for most tasks and anatomical axes, with the exception of the offset interaction calibration × axes (P < .001, ηG2=.056). Specifically, manual alignment gives the best offset estimation on the abduction/adduction and internal/external rotation axes. Therefore, we recommend the use of a static N-pose calibration procedure as the preferred IMU calibration method to model the humerothoracic joint, as this setup is the simplest as it only requires accurate positioning of the trunk sensor.

Authors

Institutions

Publication Details

Journal
Journal of Applied Biomechanics
Published
2024-11-18
DOI
https://doi.org/10.1123/jab.2023-0276
Citations
4
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
2.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Humerothoracic Joint Angles Estimation

Elisabetta Farella, Alessandro Bonfiglio, Raoul M. Bongers, David Tacconi
4 citations
Journal of Applied Biomechanics
Shoulder Injury and Treatment
2.29
article

Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Humerothoracic Joint Angles Estimation

Elisabetta Farella, Alessandro Bonfiglio, Raoul M. Bongers, David Tacconi
article en
4 citations

Abstract

Calibrating inertial measurement units (IMUs) involves converting orientation data from a local reference frame into a clinically meaningful reference system. Several solutions exist but little work has been done to compare different calibration methods with each other and an optical motion capture system. Thirteen healthy subjects with no signs of upper limb injury were recruited for this study and instrumented with IMU sensors and optical markers. Three IMU calibration methods were compared: N-pose calibration, functional calibration, and manual alignment. Subjects executed simple single-plane single-joint tasks for each upper limb joint as well as more complex multijoint tasks. We performed a 3-way analysis of variance on range of motion error, root mean squared error, and offset to assess differences between calibrations, tasks, and anatomical axes. Differences in the 3 IMU calibrations are minor and not statistically significant for most tasks and anatomical axes, with the exception of the offset interaction calibration × axes (P < .001, ηG2=.056). Specifically, manual alignment gives the best offset estimation on the abduction/adduction and internal/external rotation axes. Therefore, we recommend the use of a static N-pose calibration procedure as the preferred IMU calibration method to model the humerothoracic joint, as this setup is the simplest as it only requires accurate positioning of the trunk sensor.

Journal of Applied BiomechanicsVol. 41(1)
University Medical Center Groningen (NL), University of Trento (IT), Fondazione Bruno Kessler (IT)
Openalex Percentile: Top 11%
Shoulder Injury and Treatment
2.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.