Impact of Distributed Generation Integration on Protection Devices: A Case Study in the CIGRE European Medium Voltage Network

This study examines the impact of Inverter-Based Distributed Generators (IIDGs) on short-circuit currents detected by the main relay at the head of a radial feeder. It highlights how changes in fault currents induced by these inverter technologies can significantly affect the effectiveness and reliability of network protection systems. Key variables, such as the level of IIDGs penetration and the relative location of faults with respect to the relay, have been identified as influential factors. The significance of these findings lies in their contribution to a deeper understanding of how inverter fault responses and the integration of IIDGs alter fault currents. To mitigate the adverse effects associated with the insertion of IIDGs, a fault-detection and tripping strategy based on the inverse-time overcurrent curve is proposed. The suggested strategies not only improve fault detection accuracy but also ensure an appropriate response to variations in network conditions.

Authors

Institutions

Publication Details

Published
2024-09-23
DOI
https://doi.org/10.3390/engproc2024077009
Citations
3
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.98

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Distributed Generation Integration on Protection Devices: A Case Study in the CIGRE European Medium Voltage Network

Eduardo Orduña, Francisco González-Longatt, Le Nam Hai Pham, Veronica A. Rosero-Morillo et al.
3 citations
Power Systems Fault Detection
0.98
article

Impact of Distributed Generation Integration on Protection Devices: A Case Study in the CIGRE European Medium Voltage Network

Eduardo Orduña, Francisco González-Longatt, Le Nam Hai Pham, Veronica A. Rosero-Morillo, Eduardo Salazar, Sebastián Salazar-Pérez
article en
3 citations

Abstract

This study examines the impact of Inverter-Based Distributed Generators (IIDGs) on short-circuit currents detected by the main relay at the head of a radial feeder. It highlights how changes in fault currents induced by these inverter technologies can significantly affect the effectiveness and reliability of network protection systems. Key variables, such as the level of IIDGs penetration and the relative location of faults with respect to the relay, have been identified as influential factors. The significance of these findings lies in their contribution to a deeper understanding of how inverter fault responses and the integration of IIDGs alter fault currents. To mitigate the adverse effects associated with the insertion of IIDGs, a fault-detection and tripping strategy based on the inverse-time overcurrent curve is proposed. The suggested strategies not only improve fault detection accuracy but also ensure an appropriate response to variations in network conditions.

Loughborough University (GB), University of South-Eastern Norway (NO), National University of San Juan (AR), National Polytechnic School (EC)
Deutscher Akademischer Austauschdienst
Affordable and clean energy
Openalex Percentile: Top 23%
Power Systems Fault Detection
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.