Does the Type of Cannula Matter? A Case Report and Review of the Evidence Regarding Steel and Plastic Cannulae With Respect to a Continuous Subcutaneous Insulin Infusion

A new paradigm in the management of diabetes mellitus evolved following the introduction of continuous subcutaneous insulin infusions (CSII) into clinical practice. Outcomes include greater patient satisfaction alongside improved glycemic control. Drawbacks, however, which cannot be omitted, include patient, technology, and both patient and provider error. We present a mismatch between a patient's total daily dosage of insulin between what was expected and what was being delivered from a pump; ultimately, this required changing the infusion site and switching the type of catheter used, with resolution and improvement in clinical and glycemic status. This case is written to provide insight into one of the many complications that may be encountered with continued same-site usage of an insulin pump; moreover, strategies for management, alongside a review of the literature, are provided.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-11-18
DOI
https://doi.org/10.7759/cureus.73900
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does the Type of Cannula Matter? A Case Report and Review of the Evidence Regarding Steel and Plastic Cannulae With Respect to a Continuous Subcutaneous Insulin Infusion

Lisa Green, Jane Mayrin, Janna Prater, Maxim J Barnett
Cureus
Diabetes Management and Research
article

Does the Type of Cannula Matter? A Case Report and Review of the Evidence Regarding Steel and Plastic Cannulae With Respect to a Continuous Subcutaneous Insulin Infusion

Lisa Green, Jane Mayrin, Janna Prater, Maxim J Barnett
article en

Abstract

A new paradigm in the management of diabetes mellitus evolved following the introduction of continuous subcutaneous insulin infusions (CSII) into clinical practice. Outcomes include greater patient satisfaction alongside improved glycemic control. Drawbacks, however, which cannot be omitted, include patient, technology, and both patient and provider error. We present a mismatch between a patient's total daily dosage of insulin between what was expected and what was being delivered from a pump; ultimately, this required changing the infusion site and switching the type of catheter used, with resolution and improvement in clinical and glycemic status. This case is written to provide insight into one of the many complications that may be encountered with continued same-site usage of an insulin pump; moreover, strategies for management, alongside a review of the literature, are provided.

CureusVol. 16(11)
Jefferson Hospital (US)
Zero hunger
Openalex Percentile: Top 67%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.