Data-Driven Gas Holdup Correlation in Bubble Column Reactors Considering Alcohol Concentration and Carbon Number

Due to the complex relationship between various parameters affecting gas holdup in bubble column reactors, a unique correlation for gas holdup does not exist. The available correlations proposed in the literature for gas holdup prediction in aqueous alcohol solutions in bubble columns fail to predict gas holdup over a wide range of conditions. Therefore, based on around 1000 data points from the previous studies, an empirical correlation and a trained model were derived using the dimensionless numbers Reynolds, Froude, Eötvös to Morton ratio, and alcohol carbon number. The predictions were compared to experiments with different water–alcohol mediums at various concentrations to validate the correlation and trained model, and a good agreement was observed. However, the ML model was predicting more accurately, and it was indicated that the Reynolds number had the most significant impact on gas holdup, followed by the Eötvös to Morton ratio.

Authors

Institutions

Publication Details

Journal
ChemEngineering
Published
2024-11-18
DOI
https://doi.org/10.3390/chemengineering8060117
Primary Topic
Fluid Dynamics and Mixing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-Driven Gas Holdup Correlation in Bubble Column Reactors Considering Alcohol Concentration and Carbon Number

Salar Helchi, Mir Mehrshad Emamshoushtari, Bahram Haddadi, Babak Bonakdarpour et al.
ChemEngineering
Fluid Dynamics and Mixing
article

Data-Driven Gas Holdup Correlation in Bubble Column Reactors Considering Alcohol Concentration and Carbon Number

Salar Helchi, Mir Mehrshad Emamshoushtari, Bahram Haddadi, Babak Bonakdarpour, Farshid Pajoum Shariati
article en

Abstract

Due to the complex relationship between various parameters affecting gas holdup in bubble column reactors, a unique correlation for gas holdup does not exist. The available correlations proposed in the literature for gas holdup prediction in aqueous alcohol solutions in bubble columns fail to predict gas holdup over a wide range of conditions. Therefore, based on around 1000 data points from the previous studies, an empirical correlation and a trained model were derived using the dimensionless numbers Reynolds, Froude, Eötvös to Morton ratio, and alcohol carbon number. The predictions were compared to experiments with different water–alcohol mediums at various concentrations to validate the correlation and trained model, and a good agreement was observed. However, the ML model was predicting more accurately, and it was indicated that the Reynolds number had the most significant impact on gas holdup, followed by the Eötvös to Morton ratio.

ChemEngineeringVol. 8(6)
TU Wien (AT), Islamic Azad University, Science and Research Branch (IR), Amirkabir University of Technology (IR)
Clean water and sanitation
Openalex Percentile: Top 81%
Fluid Dynamics and Mixing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Data-Driven Gas Holdup Correlation in Bubble Column Reactors Considering Alcohol Concentration and Carbon Number — Salar Helchi, Mir Mehrshad Emamshoushtari, et al. · ChemEngineering (2024) | TGRS Research Map | TGRS