Correlation of Point of Care Ultrasound (POCUS) Guided Pupillary Assessment Parameter with Glasgow Coma Scale in Patients with Altered Mental Status– A Cross Sectional Study

Background: Earlier studies have proved deteriorating Glasgow Coma Scale (GCS) as a marker of raised intracranial pressure (ICP). Low GCS is associated with abnormal pupillary parameters. Currently, many studies have proved that ultrasound provides a feasible and objective assessment of pupillary light reflex. However, literature is lacking to evaluate objective pupillary parameters to predict GCS of the patients by point of care ultrasound (POCUS). Materials and methods: In this prospective, cross-sectional study, 200 patients were recruited in the emergency department. The inclusion criteria were patients older than 18 years with acute presentation of altered mental status. Exclusion criteria were patients who had partial globe rupture or dementia. The patients underwent a B-mode POCUS-guided evaluation at rest and after light stimulation. Statistical analysis of relationship between pupillary assessment parameters and GCS was performed using Spearman's Rank correlation coefficient, Kruskal-Wallis equality-of-populations rank test, and area under the receiver operating characteristic. Results: The study consisted of 200 (42 female, 158 male) patients with mean (± standard deviation) of age and GCS of 43.56 ± 16.50 years and 5.54 ± 3.00, respectively. Majority of non-reactive pupils had a GCS Score of 3-8 (74 cases, 97.37%). The Pupillary diameter (PD) and PD variation showed statistically significant agreement with pupil reactivity to light stimulation and GCS, with Spearman's correlation coefficient ranging from 0.28 to 0.33 for PD, and -0.55 to -0.50 (p-value <0.05) for PD variation, respectively. PD variation rate (PDVR) is the percentage change in the magnitude of constriction of PD on light stimulation. PDVR of >19.68% had a sensitivity of 86.96% (95% CI: 82.04 - 91.88%) and specificity of 64.97% (95% CI: 58.00 - 71.94%) to detect GCS>8. Conclusion: PD variation and PDVR measured by POCUS has significant correlation with GCS >8. The study showed good sensitivity and low specificity of PDVR on light stimulation to detect GCS >8.

Authors

Institutions

Publication Details

Journal
POCUS Journal
Published
2024-11-15
DOI
https://doi.org/10.24908/pocus.v9i2.17449
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation of Point of Care Ultrasound (POCUS) Guided Pupillary Assessment Parameter with Glasgow Coma Scale in Patients with Altered Mental Status– A Cross Sectional Study

Priyanka Modi, Sanjeev Bhoi
POCUS Journal
Traumatic Brain Injury and Neurovascular Disturbances
article

Correlation of Point of Care Ultrasound (POCUS) Guided Pupillary Assessment Parameter with Glasgow Coma Scale in Patients with Altered Mental Status– A Cross Sectional Study

Priyanka Modi, Sanjeev Bhoi
article en

Abstract

Background: Earlier studies have proved deteriorating Glasgow Coma Scale (GCS) as a marker of raised intracranial pressure (ICP). Low GCS is associated with abnormal pupillary parameters. Currently, many studies have proved that ultrasound provides a feasible and objective assessment of pupillary light reflex. However, literature is lacking to evaluate objective pupillary parameters to predict GCS of the patients by point of care ultrasound (POCUS). Materials and methods: In this prospective, cross-sectional study, 200 patients were recruited in the emergency department. The inclusion criteria were patients older than 18 years with acute presentation of altered mental status. Exclusion criteria were patients who had partial globe rupture or dementia. The patients underwent a B-mode POCUS-guided evaluation at rest and after light stimulation. Statistical analysis of relationship between pupillary assessment parameters and GCS was performed using Spearman's Rank correlation coefficient, Kruskal-Wallis equality-of-populations rank test, and area under the receiver operating characteristic. Results: The study consisted of 200 (42 female, 158 male) patients with mean (± standard deviation) of age and GCS of 43.56 ± 16.50 years and 5.54 ± 3.00, respectively. Majority of non-reactive pupils had a GCS Score of 3-8 (74 cases, 97.37%). The Pupillary diameter (PD) and PD variation showed statistically significant agreement with pupil reactivity to light stimulation and GCS, with Spearman's correlation coefficient ranging from 0.28 to 0.33 for PD, and -0.55 to -0.50 (p-value <0.05) for PD variation, respectively. PD variation rate (PDVR) is the percentage change in the magnitude of constriction of PD on light stimulation. PDVR of >19.68% had a sensitivity of 86.96% (95% CI: 82.04 - 91.88%) and specificity of 64.97% (95% CI: 58.00 - 71.94%) to detect GCS>8. Conclusion: PD variation and PDVR measured by POCUS has significant correlation with GCS >8. The study showed good sensitivity and low specificity of PDVR on light stimulation to detect GCS >8.

POCUS JournalVol. 9(2)
All India Institute of Medical Sciences Raipur (IN), All India Institute of Medical Sciences Bhopal (IN), All India Institute of Medical Sciences (IN)
Reduced inequalities
Openalex Percentile: Top 68%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.