Occupational radiation dose among student radiographers, nuclear medicine technologists, and radiotherapists in an Australian university

To become registered radiation worker as radiographer, nuclear medicine (NM) technologist, or radiotherapist in Australian health system, a 4-y bachelor's degree, or a 2-y master's degree in medical imaging (MI), NM, or radiation therapy (RT) approved by the Australian Health Practitioner Regulation Agency is required. During their supervised clinical practice period, it is crucial to monitor students' occupational radiation dose as their annual dose limit is 1 mSv y-1 unlike regular occupational dose of 20 mSv y-1. In this study, the distribution and trend of occupational dose among over 300 radiography, NM, and radiotherapy student practitioners per year in an Australian university are analyzed over a period of 10 y (2013-22). The overall average annual effective dose was well below the dose limit set for the students. Among the three streams-MI, NM, and RT-NM students had the highest annual dose.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-11-01
DOI
https://doi.org/10.1093/rpd/ncae160
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occupational radiation dose among student radiographers, nuclear medicine technologists, and radiotherapists in an Australian university

Pradip Deb
1 citations
Radiation Protection Dosimetry
Radiation Dose and Imaging
0.40
article

Occupational radiation dose among student radiographers, nuclear medicine technologists, and radiotherapists in an Australian university

Pradip Deb
article en
1 citations

Abstract

To become registered radiation worker as radiographer, nuclear medicine (NM) technologist, or radiotherapist in Australian health system, a 4-y bachelor's degree, or a 2-y master's degree in medical imaging (MI), NM, or radiation therapy (RT) approved by the Australian Health Practitioner Regulation Agency is required. During their supervised clinical practice period, it is crucial to monitor students' occupational radiation dose as their annual dose limit is 1 mSv y-1 unlike regular occupational dose of 20 mSv y-1. In this study, the distribution and trend of occupational dose among over 300 radiography, NM, and radiotherapy student practitioners per year in an Australian university are analyzed over a period of 10 y (2013-22). The overall average annual effective dose was well below the dose limit set for the students. Among the three streams-MI, NM, and RT-NM students had the highest annual dose.

Radiation Protection DosimetryVol. 200(16-18)
RMIT University (AU)
Openalex Percentile: Top 33%
Radiation Dose and Imaging
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.