Diagnostic Assessment of Nuclear Cataracts Using a Smartphone-Attachable Slit-Lamp Device: A Cross-Sectional Study in Vietnam

Purpose The purpose of this study was to compare the accuracy and agreement in nuclear cataract opacity classification between the Smart Eye Camera (SEC) device, and the slit-lamp. Methods A cross-sectional study was conducted with a convenient sampling of 221 eyes from 139 patients with phakic eyes, visiting IVISION Eye Center, Ho Chi Minh City, Vietnam, from November 1, 2023, to April 30, 2024. Two grading systems, Lucio-Buratto (Buratto) and World Health Organization (WHO), were used to compare the effectiveness of the two devices, with statistical analysis using Spearman's correlation coefficient and Cohen's kappa to evaluate the agreement level. Results Results showed no significant difference in Buratto and WHO grading between the two devices (p > 0.05), indicating consistency between the two measurement methods. Spearman's correlation coefficient demonstrated a strong correlation between the results from both devices, with r = 0.797 for Buratto and r = 0.579 for WHO (p < 0.001). The reliability was confirmed by high weighted-kappa values (k = 0.774 for Buratto and k = 0.539 for WHO). Conclusion The SEC's comparable effectiveness to the slit-lamp supports its potential utility in blindness-prevention screening efforts.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-11-15
DOI
https://doi.org/10.7759/cureus.73783
Citations
4
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
2.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Assessment of Nuclear Cataracts Using a Smartphone-Attachable Slit-Lamp Device: A Cross-Sectional Study in Vietnam

Nhat Vu, Hongvan Le, N Duong
4 citations
Cureus
Glaucoma and retinal disorders
2.15
article

Diagnostic Assessment of Nuclear Cataracts Using a Smartphone-Attachable Slit-Lamp Device: A Cross-Sectional Study in Vietnam

Nhat Vu, Hongvan Le, N Duong
article en
4 citations

Abstract

Purpose The purpose of this study was to compare the accuracy and agreement in nuclear cataract opacity classification between the Smart Eye Camera (SEC) device, and the slit-lamp. Methods A cross-sectional study was conducted with a convenient sampling of 221 eyes from 139 patients with phakic eyes, visiting IVISION Eye Center, Ho Chi Minh City, Vietnam, from November 1, 2023, to April 30, 2024. Two grading systems, Lucio-Buratto (Buratto) and World Health Organization (WHO), were used to compare the effectiveness of the two devices, with statistical analysis using Spearman's correlation coefficient and Cohen's kappa to evaluate the agreement level. Results Results showed no significant difference in Buratto and WHO grading between the two devices (p > 0.05), indicating consistency between the two measurement methods. Spearman's correlation coefficient demonstrated a strong correlation between the results from both devices, with r = 0.797 for Buratto and r = 0.579 for WHO (p < 0.001). The reliability was confirmed by high weighted-kappa values (k = 0.774 for Buratto and k = 0.539 for WHO). Conclusion The SEC's comparable effectiveness to the slit-lamp supports its potential utility in blindness-prevention screening efforts.

CureusVol. 16(11)
Pham Ngoc Thach University of Medicine (VN), HCMC Hospital of Dermato Venereology (VN), Eye Center (SA), Eye Care Associates (US)
Openalex Percentile: Top 12%
Glaucoma and retinal disorders
2.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnostic Assessment of Nuclear Cataracts Using a Smartphone-Attachable Slit-Lamp Device: A Cross-Sectional Study in Vietnam — Nhat Vu, Hongvan Le, et al. · Cureus (2024) | TGRS Research Map | TGRS