A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine

A novel miniaturized, solid-contact potentiometric screen-printed electrode was developed for highly sensitive and selective determination of lidocaine anesthetic. The electrode integrated single-walled carbon nanotubes as a solid-contact material and a molecularly imprinted polymer as a recognition sensory material. The performance characteristics of the electrode were evaluated and optimized to display a Nernstian slope of 58.92 ± 0.98 mV/decade over a linear concentration range of 4.53 × 10<sup>-7</sup> to 6.18 × 10<sup>-3</sup> mol/l within < 6 s. The detection limit was 7.75 × 10<sup>-8</sup> mol/l (18.16 ng/ml) of lidocaine. The use of the molecularly imprinted polymer significantly enhanced the selectivity of the electrode, and carbon nanotubes increased the sensitivity, accuracy, and potential stability. The electrode was successfully used for determining lidocaine in pharmaceutical preparations and human urine. The results favorably compared with data obtained by liquid chromatography-tandem mass spectrometry.

Authors

Institutions

Publication Details

Journal
Microchimica Acta
Published
2024-11-15
DOI
https://doi.org/10.1007/s00604-024-06802-6
Citations
9
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
2.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine

Saad S. M. Hassan, Mahmoud Abdelwahab Fathy
9 citations
Microchimica Acta
Analytical Chemistry and Sensors
2.60
article

A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine

Saad S. M. Hassan, Mahmoud Abdelwahab Fathy
article en
9 citations

Abstract

A novel miniaturized, solid-contact potentiometric screen-printed electrode was developed for highly sensitive and selective determination of lidocaine anesthetic. The electrode integrated single-walled carbon nanotubes as a solid-contact material and a molecularly imprinted polymer as a recognition sensory material. The performance characteristics of the electrode were evaluated and optimized to display a Nernstian slope of 58.92 ± 0.98 mV/decade over a linear concentration range of 4.53 × 10<sup>-7</sup> to 6.18 × 10<sup>-3</sup> mol/l within < 6 s. The detection limit was 7.75 × 10<sup>-8</sup> mol/l (18.16 ng/ml) of lidocaine. The use of the molecularly imprinted polymer significantly enhanced the selectivity of the electrode, and carbon nanotubes increased the sensitivity, accuracy, and potential stability. The electrode was successfully used for determining lidocaine in pharmaceutical preparations and human urine. The results favorably compared with data obtained by liquid chromatography-tandem mass spectrometry.

Microchimica ActaVol. 191(12)
Ain Shams University (EG)
Ain Shams University, Science and Technology Development Fund
Openalex Percentile: Top 10%
Analytical Chemistry and Sensors
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine — Saad S. M. Hassan, Mahmoud Abdelwahab Fathy · Microchimica Acta (2024) | TGRS Research Map | TGRS