Enhancement of Heat Transfer in a Pipe Fitted with Rectangular Cut Twisted Tape Inserts

This study has numerically analyzed heat transfer intensification in a pipe (U-loop) by incorporating rectangular-cut twisted tape inserts.This research uses a tubular pipe of 26.6 mm inner diameter and a 1935.62 mm long U-loop-shaped tubular pipe.The rectangular cuts are placed on one side of the twisted tape to create swirling along the flow region.From our simulation, we found the highest Nu number (357.59 at Re=17288.05) and better f (friction factor) for the tube installed with rectangular cut twisted tape insert compared to plain twisted tape and plain tube.It has also been yielded that the best thermal performance factor of 1.04 is established for rectangular-cut twisted tape inserts compared to other types.Since the rectangular cut twisted tape has increased the heat transfer rate, this concept can be used to facilitate the heat transfer rate in heat exchangers in various industrial sectors.

Authors

Publication Details

Journal
International Journal of Heat and Technology
Published
2024-10-31
DOI
https://doi.org/10.18280/ijht.420502
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancement of Heat Transfer in a Pipe Fitted with Rectangular Cut Twisted Tape Inserts

M. Bhuyan, Ujjwal Kumar Deb, Onamika Ibnath Anika
International Journal of Heat and Technology
Engineering Applied Research
article

Enhancement of Heat Transfer in a Pipe Fitted with Rectangular Cut Twisted Tape Inserts

M. Bhuyan, Ujjwal Kumar Deb, Onamika Ibnath Anika
article en

Abstract

This study has numerically analyzed heat transfer intensification in a pipe (U-loop) by incorporating rectangular-cut twisted tape inserts.This research uses a tubular pipe of 26.6 mm inner diameter and a 1935.62 mm long U-loop-shaped tubular pipe.The rectangular cuts are placed on one side of the twisted tape to create swirling along the flow region.From our simulation, we found the highest Nu number (357.59 at Re=17288.05) and better f (friction factor) for the tube installed with rectangular cut twisted tape insert compared to plain twisted tape and plain tube.It has also been yielded that the best thermal performance factor of 1.04 is established for rectangular-cut twisted tape inserts compared to other types.Since the rectangular cut twisted tape has increased the heat transfer rate, this concept can be used to facilitate the heat transfer rate in heat exchangers in various industrial sectors.

International Journal of Heat and TechnologyVol. 42(5)
Mahidol University
Affordable and clean energy
Openalex Percentile: Top 77%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancement of Heat Transfer in a Pipe Fitted with Rectangular Cut Twisted Tape Inserts — M. Bhuyan, Ujjwal Kumar Deb, et al. · International Journal of Heat and Technology (2024) | TGRS Research Map | TGRS