Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center prospective study

PurposeThis study aims to compare the 3-month clinical outcomes between two enhanced monofocal intraocular lenses (IOLs) following cataract surgery.Setting: Eye Clinic of Careggi University Hospital, Florence, Italy.DesignSingle-center prospective study.MethodsWe included patients with cataract and corneal astigmatism less than 0.75 D, with no ocular comorbidities, who underwent unilateral cataract surgery with implantation of either the Tecnis Eyhance ICB00 (<i>N</i> = 25) or Evolux (<i>N</i> = 25) IOLs. Standard cataract procedures were performed without complications. The main outcome measures included uncorrected and corrected visual acuity at distance (4 m), intermediate (60 cm) and near (40 cm) at 3-month follow-up. Additionally, monocular defocus curves, aberrometric profiles, and perceptions of halo and glare were evaluated.ResultsThe study involved 50 patients (26 male, 24 female) with a mean age of 68 ± 8 years. Preoperative characteristics were similar between the groups, and no intraoperative or postoperative complications were reported. Statistically significant differences were observed between the groups, with the Evolux IOL showing superior results (<i>p</i> < 0.05) in terms of uncorrected and corrected visual acuity at near, intermediate, and distance, as well as in aberrometric profiles (lower-order aberration root-mean-square [RMS], higher-order aberration RMS, spherical equivalent RMS, and point spread function) and defocus curves.ConclusionsBased on our experience, while both IOLs offer substantial visual performance for intermediate and distance vision, the Evolux IOL demonstrated superior mean visual outcomes and objective parameters at the 3-month follow-up compared to the Tecnis Eyhance IOL. This indicates a potential advantage of the Evolux IOL in providing better visual performance.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2024-11-15
DOI
https://doi.org/10.1177/11206721241298031
Citations
5
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
2.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center prospective study

Fabrizio Giansanti, Vito Spagnuolo, Giulio Vicini, Alessandro Franchini et al.
5 citations
European Journal of Ophthalmology
Intraocular Surgery and Lenses
2.69
article

Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center prospective study

Fabrizio Giansanti, Vito Spagnuolo, Giulio Vicini, Alessandro Franchini, Cinzia Mazzini, Ginevra Marincolo
article en
5 citations

Abstract

PurposeThis study aims to compare the 3-month clinical outcomes between two enhanced monofocal intraocular lenses (IOLs) following cataract surgery.Setting: Eye Clinic of Careggi University Hospital, Florence, Italy.DesignSingle-center prospective study.MethodsWe included patients with cataract and corneal astigmatism less than 0.75 D, with no ocular comorbidities, who underwent unilateral cataract surgery with implantation of either the Tecnis Eyhance ICB00 (<i>N</i> = 25) or Evolux (<i>N</i> = 25) IOLs. Standard cataract procedures were performed without complications. The main outcome measures included uncorrected and corrected visual acuity at distance (4 m), intermediate (60 cm) and near (40 cm) at 3-month follow-up. Additionally, monocular defocus curves, aberrometric profiles, and perceptions of halo and glare were evaluated.ResultsThe study involved 50 patients (26 male, 24 female) with a mean age of 68 ± 8 years. Preoperative characteristics were similar between the groups, and no intraoperative or postoperative complications were reported. Statistically significant differences were observed between the groups, with the Evolux IOL showing superior results (<i>p</i> < 0.05) in terms of uncorrected and corrected visual acuity at near, intermediate, and distance, as well as in aberrometric profiles (lower-order aberration root-mean-square [RMS], higher-order aberration RMS, spherical equivalent RMS, and point spread function) and defocus curves.ConclusionsBased on our experience, while both IOLs offer substantial visual performance for intermediate and distance vision, the Evolux IOL demonstrated superior mean visual outcomes and objective parameters at the 3-month follow-up compared to the Tecnis Eyhance IOL. This indicates a potential advantage of the Evolux IOL in providing better visual performance.

European Journal of OphthalmologyVol. 35(3)
Azienda Ospedaliero-Universitaria Careggi (IT), Azienda Usl Toscana Centro (IT), University of Florence (IT)
Good health and well-being
Openalex Percentile: Top 10%
Intraocular Surgery and Lenses
2.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.