The Agreement of Intraocular Pressure Measurement in Healthy Merinos Sheep Using Rebound Tonometer (Tonovet®) and Applanation Tonometer (Tono-Pen VetTM)

The assessment of intraocular pressure (IOP) holds significant importance in ophthalmology as a crucial diagnostic tool for various ocular disorders. This study aimed to evaluate the agreement between rebound (TonoVet®, TV) and applanation (Tono-Pen Vet™, TPV) tonometers in measuring IOP in healthy Merino sheep. 155 healthy Merinos (80 males, 75 females) with a mean weight of 54.4±8.7 kg, aged 24±6 months, were included in the study. IOP was measured between 9:00 and 11:00 am using both the rebound and applanation tonometers. The rebound tonometer was used first, followed by the applanation tonometer. A total of 620 readings (310 readings for each tonometer) were obtained from the two devices. No statistical differences were noted between the mean IOP measurements of the right and left eyes for both tonometers (p>0.05). However, there was a significant difference in the mean IOP measurements between the TV (11.8±2.3 mmHg) and the TPV (13.9±2.9 mmHg) tonometers (p

Authors

Institutions

Publication Details

Journal
Van veterinary journal
Published
2024-11-15
DOI
https://doi.org/10.36483/vanvetj.1513839
Citations
1
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Agreement of Intraocular Pressure Measurement in Healthy Merinos Sheep Using Rebound Tonometer (Tonovet®) and Applanation Tonometer (Tono-Pen VetTM)

Ferda Turgut, Ömer Tarık Orhun, Sıtkıcan Okur, Uğur Ersöz et al.
1 citations
Van veterinary journal
Corneal surgery and disorders
0.40
article

The Agreement of Intraocular Pressure Measurement in Healthy Merinos Sheep Using Rebound Tonometer (Tonovet®) and Applanation Tonometer (Tono-Pen VetTM)

Ferda Turgut, Ömer Tarık Orhun, Sıtkıcan Okur, Uğur Ersöz, Latif Emrah Yanmaz, Ayşe Gölgeli Bedir, Yakup Kocaman, Mümin Gökhan Şenocak, Esra Modoğlu
article en
1 citations

Abstract

The assessment of intraocular pressure (IOP) holds significant importance in ophthalmology as a crucial diagnostic tool for various ocular disorders. This study aimed to evaluate the agreement between rebound (TonoVet®, TV) and applanation (Tono-Pen Vet™, TPV) tonometers in measuring IOP in healthy Merino sheep. 155 healthy Merinos (80 males, 75 females) with a mean weight of 54.4±8.7 kg, aged 24±6 months, were included in the study. IOP was measured between 9:00 and 11:00 am using both the rebound and applanation tonometers. The rebound tonometer was used first, followed by the applanation tonometer. A total of 620 readings (310 readings for each tonometer) were obtained from the two devices. No statistical differences were noted between the mean IOP measurements of the right and left eyes for both tonometers (p>0.05). However, there was a significant difference in the mean IOP measurements between the TV (11.8±2.3 mmHg) and the TPV (13.9±2.9 mmHg) tonometers (p

Van veterinary journalVol. 35(3)
Yozgat Bozok Üniversitesi (TR), Necmettin Erbakan University (TR), Burdur Mehmet Akif Ersoy Üniversitesi (TR), Atatürk University (TR)
Quality Education
Openalex Percentile: Top 33%
Corneal surgery and disorders
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Agreement of Intraocular Pressure Measurement in Healthy Merinos Sheep Using Rebound Tonometer (Tonovet®) and Applanation Tonometer (Tono-Pen VetTM) — Ferda Turgut, Ömer Tarık Orhun, et al. · Van veterinary journal (2024) | TGRS Research Map | TGRS