MIMIC-BP: A curated dataset for blood pressure estimation

Blood pressure (BP) is one of the most prominent indicators of potential cardiovascular disorders. Traditionally, BP measurement relies on inflatable cuffs, which is inconvenient and limit the acquisition of such important health-related information in general population. Based on large amounts of well-collected and annotated data, deep-learning approaches present a generalization potential that arose as an alternative to enable more pervasive approaches. However, most existing work in this area currently uses datasets with limitations, such as lack of subject identification and severe data imbalance that can result in data leakage and algorithm bias. Thus, to offer a more properly curated source of information, we propose a derivative dataset composed of 380 hours of the most common biomedical signals, including arterial blood pressure, photoplethysmography, and electrocardiogram for 1,524 anonymized subjects, each having 30 segments of 30 seconds of those signals. We also validated the proposed dataset through experiments using state-of-the-art deep-learning methods, as we highlight the importance of standardized benchmarks for calibration-free blood pressure estimation scenarios.

Authors

Institutions

Publication Details

Journal
Scientific Data
Published
2024-11-15
DOI
https://doi.org/10.1038/s41597-024-04041-1
Citations
9
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MIMIC-BP: A curated dataset for blood pressure estimation

Otávio A. B. Penatti, Vinícius Horn Cene, Ivandro Sanches, Carlos Caetano et al.
9 citations
Scientific Data
Non-Invasive Vital Sign Monitoring
1.66
article

MIMIC-BP: A curated dataset for blood pressure estimation

Otávio A. B. Penatti, Vinícius Horn Cene, Ivandro Sanches, Carlos Caetano, Thomas Beltrame, Sanghyun Baek, Victor V. Gomes, Lizeth S. B. Cabrera, Wonkyu Lee
article en
9 citations

Abstract

Blood pressure (BP) is one of the most prominent indicators of potential cardiovascular disorders. Traditionally, BP measurement relies on inflatable cuffs, which is inconvenient and limit the acquisition of such important health-related information in general population. Based on large amounts of well-collected and annotated data, deep-learning approaches present a generalization potential that arose as an alternative to enable more pervasive approaches. However, most existing work in this area currently uses datasets with limitations, such as lack of subject identification and severe data imbalance that can result in data leakage and algorithm bias. Thus, to offer a more properly curated source of information, we propose a derivative dataset composed of 380 hours of the most common biomedical signals, including arterial blood pressure, photoplethysmography, and electrocardiogram for 1,524 anonymized subjects, each having 30 segments of 30 seconds of those signals. We also validated the proposed dataset through experiments using state-of-the-art deep-learning methods, as we highlight the importance of standardized benchmarks for calibration-free blood pressure estimation scenarios.

Scientific DataVol. 11(1)
Samsung (South Korea) (KR), Samsung (Brazil) (BR)
Samsung Eletrônica da Amazônia, Samsung
Openalex Percentile: Top 17%
Non-Invasive Vital Sign Monitoring
1.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.