Location Method of Buried Polyethylene Gas Pipeline Based on Acoustic Signal Ellipse Method

This study proposes a buried PE gas pipeline positioning method based on the elliptical method of an acoustic signal analysis. The cross-correlation time delay positioning technology is combined with the elliptical equation, forming an effective mechanism for pipeline depth positioning. First, a dual-tree complex wavelet transform is employed to denoise the collected signals, enhancing the quality and accuracy of the data. Subsequently, the cross-correlation function is utilized to extract the delay times between the signals. The obtained delay times are then substituted into the elliptical equation to calculate the depth of the buried PE pipeline. Based on this theoretical framework, a simulation model is established in COMSOL, and positioning simulation analyses are conducted under three different conditions: pipeline depth, relative sensor positions, and distances between sensors and excitation points. The simulation results indicate that a clear correlation exists between the signal delay time and the pipeline position, with simulation errors controlled within 5%, thus validating the theoretical feasibility of the method. To further assess the effectiveness of this approach, an experimental testing system is constructed. The experimental study was carried out under four different conditions: pipeline burial depth, relative sensor positions, distances between sensors and excitation points, and excitation frequencies. The experimental results demonstrate that these factors significantly affect the pipeline depth positioning. The comparison results show that the method has a high accuracy in depth positioning, with experimental errors controlled within 10%. This study proves that accurate positioning of pipeline depth could be achieved by substituting signal delay times into the elliptical equation, thereby validating the method's feasibility in practical applications. The proposed method effectively addressed the shortcomings of existing pipeline depth positioning technologies, providing important theoretical support and a practical reference for future pipeline positioning research.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-15
DOI
https://doi.org/10.3390/s24227302
Citations
3
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.78

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Location Method of Buried Polyethylene Gas Pipeline Based on Acoustic Signal Ellipse Method

Ao Zhang, Xianfa Liu, Xianchao Sun, Zhuo Xu et al.
3 citations
Sensors
Water Systems and Optimization
0.78
article

Location Method of Buried Polyethylene Gas Pipeline Based on Acoustic Signal Ellipse Method

Ao Zhang, Xianfa Liu, Xianchao Sun, Zhuo Xu, Hanyu Zhang, Yang Li, Pengyao Sun
article en
3 citations

Abstract

This study proposes a buried PE gas pipeline positioning method based on the elliptical method of an acoustic signal analysis. The cross-correlation time delay positioning technology is combined with the elliptical equation, forming an effective mechanism for pipeline depth positioning. First, a dual-tree complex wavelet transform is employed to denoise the collected signals, enhancing the quality and accuracy of the data. Subsequently, the cross-correlation function is utilized to extract the delay times between the signals. The obtained delay times are then substituted into the elliptical equation to calculate the depth of the buried PE pipeline. Based on this theoretical framework, a simulation model is established in COMSOL, and positioning simulation analyses are conducted under three different conditions: pipeline depth, relative sensor positions, and distances between sensors and excitation points. The simulation results indicate that a clear correlation exists between the signal delay time and the pipeline position, with simulation errors controlled within 5%, thus validating the theoretical feasibility of the method. To further assess the effectiveness of this approach, an experimental testing system is constructed. The experimental study was carried out under four different conditions: pipeline burial depth, relative sensor positions, distances between sensors and excitation points, and excitation frequencies. The experimental results demonstrate that these factors significantly affect the pipeline depth positioning. The comparison results show that the method has a high accuracy in depth positioning, with experimental errors controlled within 10%. This study proves that accurate positioning of pipeline depth could be achieved by substituting signal delay times into the elliptical equation, thereby validating the method's feasibility in practical applications. The proposed method effectively addressed the shortcomings of existing pipeline depth positioning technologies, providing important theoretical support and a practical reference for future pipeline positioning research.

SensorsVol. 24(22)
Northeast Electric Power University (CN), Shenyang Jianzhu University (CN)
People's Government of Jilin Province
Openalex Percentile: Top 29%
Water Systems and Optimization
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.