Strip electrodes: a novel, effective and minimally invasive therapeutic option for correcting DNS <i>via</i> electromechanical reshaping

Deviated nasal septum (DNS) is a common condition affecting nasal breathing, which is generally treated using septoplasty. However, this invasive surgical method carries potential risks of post-surgical complications. Alternatively, electromechanical reshaping (EMR) is a novel method that has evolved as a non-thermal, minimally invasive option to reshape the cartilage using mechanical pressure and direct current (DC) without significant tissue damage. However, the existing flat and needle electrodes tested in animal tissues have raised significant concerns due to their safety. Thus, herein, we aimed to develop a novel strip electrode configuration and optimize dosimetry to achieve efficient reshaping without compromising its safety. Electric field simulations showed that our novel 5-strip electrode configuration with a thickness of 0.5 mm achieved optimal electric field, requiring minimal current flow compared to flat electrodes. EMR was performed on <i>ex vivo</i> goat cartilage at various dosimetry groups to analyze four-day shape retention. The optimized strip electrode reshaped the <i>ex vivo</i> goat septal cartilage effectively at a dosimetry of 20 mA for 15 minutes, whereas the flat electrode needed 35 mA for 15 minutes. DMMB assay, ATR-FTIR spectroscopy, tensile testing, and histopathology analysis demonstrated reduced tissue damage while supporting increased efficiency and mechanical stability with the strip electrode configuration, emphasizing its safety. Thus, the optimized strip electrode-based EMR emerges as a viable non-invasive approach for reshaping the nasal septal cartilage, which can be used to treat DNS. Further <i>in vivo</i> studies are recommended to validate the long-term safety and efficacy of this technique.

Authors

Institutions

Publication Details

Journal
Journal of Materials Chemistry B
Published
2024-11-15
DOI
https://doi.org/10.1039/d4tb01306a
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strip electrodes: a novel, effective and minimally invasive therapeutic option for correcting DNS via electromechanical reshaping

Amit Goyal, Gowri Manohari Balachander, Ajay Agarwal, Mohamed Jameer Basha Jahankir et al.
1 citations
Journal of Materials Chemistry B
Advanced biosensing and bioanalysis techniques
0.23
article

Strip electrodes: a novel, effective and minimally invasive therapeutic option for correcting DNS via electromechanical reshaping

Amit Goyal, Gowri Manohari Balachander, Ajay Agarwal, Mohamed Jameer Basha Jahankir, H. Ramesh, Thilak Chakaravarthi
article en
1 citations

Abstract

Deviated nasal septum (DNS) is a common condition affecting nasal breathing, which is generally treated using septoplasty. However, this invasive surgical method carries potential risks of post-surgical complications. Alternatively, electromechanical reshaping (EMR) is a novel method that has evolved as a non-thermal, minimally invasive option to reshape the cartilage using mechanical pressure and direct current (DC) without significant tissue damage. However, the existing flat and needle electrodes tested in animal tissues have raised significant concerns due to their safety. Thus, herein, we aimed to develop a novel strip electrode configuration and optimize dosimetry to achieve efficient reshaping without compromising its safety. Electric field simulations showed that our novel 5-strip electrode configuration with a thickness of 0.5 mm achieved optimal electric field, requiring minimal current flow compared to flat electrodes. EMR was performed on <i>ex vivo</i> goat cartilage at various dosimetry groups to analyze four-day shape retention. The optimized strip electrode reshaped the <i>ex vivo</i> goat septal cartilage effectively at a dosimetry of 20 mA for 15 minutes, whereas the flat electrode needed 35 mA for 15 minutes. DMMB assay, ATR-FTIR spectroscopy, tensile testing, and histopathology analysis demonstrated reduced tissue damage while supporting increased efficiency and mechanical stability with the strip electrode configuration, emphasizing its safety. Thus, the optimized strip electrode-based EMR emerges as a viable non-invasive approach for reshaping the nasal septal cartilage, which can be used to treat DNS. Further <i>in vivo</i> studies are recommended to validate the long-term safety and efficacy of this technique.

Journal of Materials Chemistry BVol. 13(2)
Indian Institute of Technology Jodhpur (IN), Centre for Cellular and Molecular Biology (IN), All India Institute of Medical Sciences Jodhpur (IN), Indian Institute of Technology BHU (IN), Banaras Hindu University (IN)
Science and Engineering Research Board
Zero hunger
Openalex Percentile: Top 41%
Advanced biosensing and bioanalysis techniques
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.