Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods

Architect-HIV Ag/Ab combo chemiluminescence assay is globally recognized for its sensitivity but has a notable false-positive rate. In this study, we aim to evaluate the performance of a new cost-effective screening alternative, the chemiluminescence Ag/Ab combo assay (CL-900i-HIV) from Mindray, China. We selected 195 archived samples categorized according to the INNO-LIA™ HIV I/II, the gold standard confirmatory assay. These samples included true positive (n = 38; positive by Architect-HIV & INNO-LIA-HIV), true negative (n = 101; negative by Architect-HIV & INNO-LIA-HIV), false positive (n = 20; positive by Architect-HIV & negative by INNO-LIA-HIV), and indeterminate results (n = 26). We tested all samples using the Mindray CL-900i-HIV and all positive Architect-HIV samples (n = 80) were confirmed by PCR. Compared to INNO-LIA™ HIVI/II line immunoassay confirmatory assay, Mindray CL-900i-HIV demonstrated a sensitivity of 100% (95% CI 90.7-100), specificity of 100% (95% CI 97.0-100), overall percent agreement (OPA) of 100% (95% CI 97.7-100.0), and perfect agreement with the INNO-LIA confirmatory assay (κ = 1.00). Additionally, Mindray's CL-900i-HIV exhibited a significantly lower false-positive rate (8.75%) compared to Architect-HIV's (55%). Mindray CL900i demonstrated high sensitivity and very low false-positive rate, thus, has the potential to serve as an excellent, cost-effective surrogate for HIV screening, overcoming the limitations of existing automated assays.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-15
DOI
https://doi.org/10.1038/s41598-024-78271-z
Citations
3
Primary Topic
HIV Research and Treatment
Type
article
Field-Weighted Citation Impact
0.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods

Laith Jamal Abu-Raddad, Gheyath K. Nasrallah, Ahmed Ismail, Hadi Mohamad Yassine et al.
3 citations
Scientific Reports
HIV Research and Treatment
0.88
article

Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods

Laith Jamal Abu-Raddad, Gheyath K. Nasrallah, Ahmed Ismail, Hadi Mohamad Yassine, Mutaz Mohamed Ali, Ibrahim Al Shaar, Salma Younes, Houssein H. Ayoub, Jawaher A. Al-Emadi, Hadiya M. Khalid, Mazen Najib Abouassali, Ibrahim Wisam Karime, Na Liu, Nadin Younes, Mohammed Abdelfatah Ibrahim, Manal Elshaikh
article en
3 citations

Abstract

Architect-HIV Ag/Ab combo chemiluminescence assay is globally recognized for its sensitivity but has a notable false-positive rate. In this study, we aim to evaluate the performance of a new cost-effective screening alternative, the chemiluminescence Ag/Ab combo assay (CL-900i-HIV) from Mindray, China. We selected 195 archived samples categorized according to the INNO-LIA™ HIV I/II, the gold standard confirmatory assay. These samples included true positive (n = 38; positive by Architect-HIV & INNO-LIA-HIV), true negative (n = 101; negative by Architect-HIV & INNO-LIA-HIV), false positive (n = 20; positive by Architect-HIV & negative by INNO-LIA-HIV), and indeterminate results (n = 26). We tested all samples using the Mindray CL-900i-HIV and all positive Architect-HIV samples (n = 80) were confirmed by PCR. Compared to INNO-LIA™ HIVI/II line immunoassay confirmatory assay, Mindray CL-900i-HIV demonstrated a sensitivity of 100% (95% CI 90.7-100), specificity of 100% (95% CI 97.0-100), overall percent agreement (OPA) of 100% (95% CI 97.7-100.0), and perfect agreement with the INNO-LIA confirmatory assay (κ = 1.00). Additionally, Mindray's CL-900i-HIV exhibited a significantly lower false-positive rate (8.75%) compared to Architect-HIV's (55%). Mindray CL900i demonstrated high sensitivity and very low false-positive rate, thus, has the potential to serve as an excellent, cost-effective surrogate for HIV screening, overcoming the limitations of existing automated assays.

Scientific ReportsVol. 14(1)
Cornell University (US), Ministry of Public Health (QA), Weill Cornell Medical College in Qatar (QA), Mindray (China) (CN), Qatar University (QA)
Qatar University, Qatar National Research Fund
Good health and well-being
Openalex Percentile: Top 25%
HIV Research and Treatment
0.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.