Inducible displacement of cementless total knee arthroplasty components with conventional and weight‐bearing CT‐based radiostereometric analysis

Aseptic loosening remains one of the top causes of revision surgery of total knee arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure implant migration, however limitations prevent its clinical use. New methods have allowed the same measurements as RSA to be performed with computed tomography (CT) scanners (CT-RSA). The objective of this study is to determine inducible displacement measurements from weight-bearing computed tomography (WBCT) and conventional RSA to assess implant stability. Participants (n = 17) completed RSA exams in the supine and standing position, and WBCT exams in the seated (leg extended) and standing position. Double examinations were performed in the seated (WBCT) or supine (RSA) positions. Inducible displacements were measured with model-based RSA (MBRSA) for RSA exams, and a novel CT-RSA software, V3MA, for WBCT exams. Precision of each technique was calculated between double examinations. Precision data for tibial component total translations and rotations were 0.05 mm and 0.118°, respectively with WBCT-RSA, and were 0.108 mm and 0.269°, respectively with MBRSA. MTPM precision was 0.141 mm with WBCT-RSA and was 0.168 mm with MBRSA. Inducible displacement MTPM of the tibial component was 0.244 ± 0.220 mm with WBCT-RSA and 0.662 ± 0.257 mm with MBRSA. Inducible displacement measurements with MBRSA were significantly different from WBCT-RSA for tibial component anterior tilt (p = 0.0002). WBCT-RSA demonstrated comparable precision to MBRSA, and both techniques measured inducible displacements consistent with stable components. Clinical Significance: As the availability of WBCT increases, its use as an alternative to MBRSA is supported to measure the instantaneous fixation of implant components.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2024-11-15
DOI
https://doi.org/10.1002/jor.26017
Citations
8
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
4.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inducible displacement of cementless total knee arthroplasty components with conventional and weight‐bearing CT‐based radiostereometric analysis

Bart L. Kaptein, Brent A. Lanting, Matthew G. Teeter, James L. Howard et al.
8 citations
Journal of Orthopaedic Research®
Total Knee Arthroplasty Outcomes
4.58
article

Inducible displacement of cementless total knee arthroplasty components with conventional and weight‐bearing CT‐based radiostereometric analysis

Bart L. Kaptein, Brent A. Lanting, Matthew G. Teeter, James L. Howard, Rebecca A. Hext
article en
8 citations

Abstract

Aseptic loosening remains one of the top causes of revision surgery of total knee arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure implant migration, however limitations prevent its clinical use. New methods have allowed the same measurements as RSA to be performed with computed tomography (CT) scanners (CT-RSA). The objective of this study is to determine inducible displacement measurements from weight-bearing computed tomography (WBCT) and conventional RSA to assess implant stability. Participants (n = 17) completed RSA exams in the supine and standing position, and WBCT exams in the seated (leg extended) and standing position. Double examinations were performed in the seated (WBCT) or supine (RSA) positions. Inducible displacements were measured with model-based RSA (MBRSA) for RSA exams, and a novel CT-RSA software, V3MA, for WBCT exams. Precision of each technique was calculated between double examinations. Precision data for tibial component total translations and rotations were 0.05 mm and 0.118°, respectively with WBCT-RSA, and were 0.108 mm and 0.269°, respectively with MBRSA. MTPM precision was 0.141 mm with WBCT-RSA and was 0.168 mm with MBRSA. Inducible displacement MTPM of the tibial component was 0.244 ± 0.220 mm with WBCT-RSA and 0.662 ± 0.257 mm with MBRSA. Inducible displacement measurements with MBRSA were significantly different from WBCT-RSA for tibial component anterior tilt (p = 0.0002). WBCT-RSA demonstrated comparable precision to MBRSA, and both techniques measured inducible displacements consistent with stable components. Clinical Significance: As the availability of WBCT increases, its use as an alternative to MBRSA is supported to measure the instantaneous fixation of implant components.

Journal of Orthopaedic Research®Vol. 43(3)
Western University (CA), Leiden University Medical Center (NL)
Arthritis Society
Openalex Percentile: Top 5%
Total Knee Arthroplasty Outcomes
4.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.