Design and fabrication of a dual laser Raman spectrometer with a single one-dimensional CCD detector

The combination of two spectrometers in dual-laser Raman devices without the need for moving parts represents a significant advancement. This study focuses on design and fabrication of a dual spectrometer with no moving components, allowing data to be gathered using a single detector. This instrument consists of two Czerny-Turner optical arrangements which is symmetrically merged. Dual spectrometer single detector has two light inputs, each of them, concentrating the light separately on a one linear charge-coupled device detector through two independent optical paths. In this innovative spectrometer design, no optical moving parts are used, and therefore, the wavelength displacement error in repeating the spectroscopic experiment is zero. The independent nature of the optical paths enables the optimization of each spectrometer arrangement without affecting the other. The final spectrometer has a spectral resolution of 4.6 and 6.11 cm<sup>- 1</sup> for Full Width at Half Maximum across the wavelength ranges of 532 to 708 nm and 784.65 to 1100 nm, respectively. Switching between the two different acquisition setups can be done seamlessly and quickly, with the ability to record approximately 2000 spectra per second. Standard neon and mercury-argon lamps' atomic radiation spectra, along with Raman scattering data from a cyclohexane standard sample, were successfully recorded using laser wavelengths of 532 nm and 784.65 nm.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-15
DOI
https://doi.org/10.1038/s41598-024-79882-2
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and fabrication of a dual laser Raman spectrometer with a single one-dimensional CCD detector

Seyed Hassan Tavassoli, Omid Badkoobe Hezave
1 citations
Scientific Reports
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
article

Design and fabrication of a dual laser Raman spectrometer with a single one-dimensional CCD detector

Seyed Hassan Tavassoli, Omid Badkoobe Hezave
article en
1 citations

Abstract

The combination of two spectrometers in dual-laser Raman devices without the need for moving parts represents a significant advancement. This study focuses on design and fabrication of a dual spectrometer with no moving components, allowing data to be gathered using a single detector. This instrument consists of two Czerny-Turner optical arrangements which is symmetrically merged. Dual spectrometer single detector has two light inputs, each of them, concentrating the light separately on a one linear charge-coupled device detector through two independent optical paths. In this innovative spectrometer design, no optical moving parts are used, and therefore, the wavelength displacement error in repeating the spectroscopic experiment is zero. The independent nature of the optical paths enables the optimization of each spectrometer arrangement without affecting the other. The final spectrometer has a spectral resolution of 4.6 and 6.11 cm<sup>- 1</sup> for Full Width at Half Maximum across the wavelength ranges of 532 to 708 nm and 784.65 to 1100 nm, respectively. Switching between the two different acquisition setups can be done seamlessly and quickly, with the ability to record approximately 2000 spectra per second. Standard neon and mercury-argon lamps' atomic radiation spectra, along with Raman scattering data from a cyclohexane standard sample, were successfully recorded using laser wavelengths of 532 nm and 784.65 nm.

Scientific ReportsVol. 14(1)
Shahid Beheshti University (IR)
Affordable and clean energy
Openalex Percentile: Top 19%
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and fabrication of a dual laser Raman spectrometer with a single one-dimensional CCD detector — Seyed Hassan Tavassoli, Omid Badkoobe Hezave · Scientific Reports (2024) | TGRS Research Map | TGRS