An Intelligent Antibacterial Hydrogel Coating with Triple Antifouling–Killing–Releasing Functions for Medical Tubing

The bacterial contamination of dental unit waterline (DUWL) output water has been reported in many areas, posing a potential risk to patients and dental healthcare staff. As a common method for addressing bacterial contamination, it is still a challenge for the disinfecting solution to provide enduring antibacterial activity. Herein, an approach to developing an intelligent antibacterial hydrogel coating with a dual-layer structure on polyurethane (PU) is reported in this study to control bacterial contamination on the inner surfaces of the DUWL tubing. The antifouling lower layer, derived from sulfobetaine methacrylate and 2-hydroxyethyl methacrylate, and a bactericidal upper layer consisting of poly-l-lysine (PLys) were sequentially grafted on the surface of PU. The antifouling and bactericidal layers were connected by the Schiff base structure. The results of scanning electron microscopy indicated the successful synthesis of the hydrogel coating with the thickness of 30.7 μm. Peaks at 399.85 eV (N 1s) in X-ray photoelectron spectroscopy spectra and 1653 cm–1 in Fourier transform infrared spectra represented the formation of Schiff base structure. Besides, the hydrophilicity assay found a decrease in water contact angle from 98.471 ± 3.208° to 54.594 ± 1.156°, indicating the great hydrophilicity of the hydrogel coating. In vitro antibacterial experiments revealed that there were a few dead bacteria adhered to the surface of the hydrogel coating. When treated with an acidic solution, most of the dead bacteria were released. Following the regrafting of PLys, only a small amount of dead bacteria were observed on the surface of the hydrogel coating. It was found that the hydrogel coating showed antifouling–killing–releasing functions as well as regeneration properties. Moreover, the hydrogel coating exhibited great stability and favorable biocompatibility. Thus, the hydrogel coating with triple functions (antifouling–killing–releasing) is capable of constructing an intelligent PU surface and has potential for reducing bacterial adhesion to DUWL tubing in clinical applications.

Authors

Institutions

Publication Details

Journal
ACS Applied Polymer Materials
Published
2024-11-15
DOI
https://doi.org/10.1021/acsapm.4c02680
Citations
6
Primary Topic
Polymer Surface Interaction Studies
Type
article
Field-Weighted Citation Impact
1.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Intelligent Antibacterial Hydrogel Coating with Triple Antifouling–Killing–Releasing Functions for Medical Tubing

Yuedan Xu, Qi Gao, Ling Zhang, Lin Ye et al.
6 citations
ACS Applied Polymer Materials
Polymer Surface Interaction Studies
1.07
article

An Intelligent Antibacterial Hydrogel Coating with Triple Antifouling–Killing–Releasing Functions for Medical Tubing

Yuedan Xu, Qi Gao, Ling Zhang, Lin Ye, Xiaolu Chen, Xiangxing Kong, Yi Sun, Xinni Pan
article en
6 citations

Abstract

The bacterial contamination of dental unit waterline (DUWL) output water has been reported in many areas, posing a potential risk to patients and dental healthcare staff. As a common method for addressing bacterial contamination, it is still a challenge for the disinfecting solution to provide enduring antibacterial activity. Herein, an approach to developing an intelligent antibacterial hydrogel coating with a dual-layer structure on polyurethane (PU) is reported in this study to control bacterial contamination on the inner surfaces of the DUWL tubing. The antifouling lower layer, derived from sulfobetaine methacrylate and 2-hydroxyethyl methacrylate, and a bactericidal upper layer consisting of poly-l-lysine (PLys) were sequentially grafted on the surface of PU. The antifouling and bactericidal layers were connected by the Schiff base structure. The results of scanning electron microscopy indicated the successful synthesis of the hydrogel coating with the thickness of 30.7 μm. Peaks at 399.85 eV (N 1s) in X-ray photoelectron spectroscopy spectra and 1653 cm–1 in Fourier transform infrared spectra represented the formation of Schiff base structure. Besides, the hydrophilicity assay found a decrease in water contact angle from 98.471 ± 3.208° to 54.594 ± 1.156°, indicating the great hydrophilicity of the hydrogel coating. In vitro antibacterial experiments revealed that there were a few dead bacteria adhered to the surface of the hydrogel coating. When treated with an acidic solution, most of the dead bacteria were released. Following the regrafting of PLys, only a small amount of dead bacteria were observed on the surface of the hydrogel coating. It was found that the hydrogel coating showed antifouling–killing–releasing functions as well as regeneration properties. Moreover, the hydrogel coating exhibited great stability and favorable biocompatibility. Thus, the hydrogel coating with triple functions (antifouling–killing–releasing) is capable of constructing an intelligent PU surface and has potential for reducing bacterial adhesion to DUWL tubing in clinical applications.

ACS Applied Polymer MaterialsVol. 6(23)
Stomatology Hospital (CN), Second Affiliated Hospital of Zhejiang University (CN), Zhejiang University (CN)
Natural Science Foundation of Zhejiang Province
Clean water and sanitation
Openalex Percentile: Top 25%
Polymer Surface Interaction Studies
1.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.