Predictive Maintenance Edge Artificial Intelligence Application Study Using Recurrent Neural Networks for Early Aging Detection in Peristaltic Pumps

Peristaltic pumps are widely used in many industrial applications, especially in medical devices. Their reliability depends on proper maintenance, which includes the total replacement of tubes regularly due to the aging of the materials. The proper use of predictive maintenance techniques could potentially improve the efficiency of maintenance interventions and prevent failures by having a way to determine when the tube has passed its replacement time. We recorded a dataset using six different sensors (three accelerometers, one gyroscope, one magnetometer, and one microphone) using several cassettes (three new units and three units with expired life span). The recording was done at the highest possible frequency (100–6667 Hz, different for each sensor) and then downsampled several times to obtain frequencies as low as 12 Hz. This dataset is now publicly available. We trained 939 different models, which were the result of combining all different sensors as inputs but the microphone, and four basic architectures of recurrent neural network: One or two layers of either gated recurrent unit or long short-term memory with different number of nodes per layer (from 2 to 64). Among all trained models, we selected the ten best performing networks in terms of both accuracy and complexity. All of them reached an F1 score of 0.99 or 1 with holdout cross-validation. Those models were deployed on four different edge AI devices. For all combinations of model and edge AI devices we obtained metrics of memory size (from 0.3% to 160.6% RAM, and from 0.9% to 21.3% flash), inference time (from 0.39 to 1463.91 ms), and average consumption (from 0.15 to 5.30 mA). Nine out of ten models were proven viable for deployment. We concluded that the four models based on magnetometer data were significantly better in terms of consumption and inference time. To the best of our knowledge, the use of magnetometer data is a very uncommon approach to failure detection in predictive maintenance applications, and this is probably the first time it has been used for peristaltic pump aging detection, so our results are very promising for future applications. Also, since most trained models use little resources, we have proved that our approach is perfectly compatible with running other communication and control algorithms on the same device, which is ideal for easy integration and scalability in industrial systems. Some limitations for real deployment include facing environmental factors (noise) and long-term monitoring, so we also proposed a protocol that should reduce the impact of those factors by taking measurements in a controlled way.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Reliability
Published
2024-11-15
DOI
https://doi.org/10.1109/tr.2024.3488963
Citations
7
Primary Topic
Belt Conveyor Systems Engineering
Type
article
Field-Weighted Citation Impact
1.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictive Maintenance Edge Artificial Intelligence Application Study Using Recurrent Neural Networks for Early Aging Detection in Peristaltic Pumps

Yoshifumi Nishio, Ángel Jiménez-Fernández, Saturnino Vicente-Díaz, Yoko Uwate et al.
7 citations
IEEE Transactions on Reliability
Belt Conveyor Systems Engineering
1.49
article

Predictive Maintenance Edge Artificial Intelligence Application Study Using Recurrent Neural Networks for Early Aging Detection in Peristaltic Pumps

Yoshifumi Nishio, Ángel Jiménez-Fernández, Saturnino Vicente-Díaz, Yoko Uwate, Juan M. Montes-Sánchez
article en
7 citations

Abstract

Peristaltic pumps are widely used in many industrial applications, especially in medical devices. Their reliability depends on proper maintenance, which includes the total replacement of tubes regularly due to the aging of the materials. The proper use of predictive maintenance techniques could potentially improve the efficiency of maintenance interventions and prevent failures by having a way to determine when the tube has passed its replacement time. We recorded a dataset using six different sensors (three accelerometers, one gyroscope, one magnetometer, and one microphone) using several cassettes (three new units and three units with expired life span). The recording was done at the highest possible frequency (100–6667 Hz, different for each sensor) and then downsampled several times to obtain frequencies as low as 12 Hz. This dataset is now publicly available. We trained 939 different models, which were the result of combining all different sensors as inputs but the microphone, and four basic architectures of recurrent neural network: One or two layers of either gated recurrent unit or long short-term memory with different number of nodes per layer (from 2 to 64). Among all trained models, we selected the ten best performing networks in terms of both accuracy and complexity. All of them reached an F1 score of 0.99 or 1 with holdout cross-validation. Those models were deployed on four different edge AI devices. For all combinations of model and edge AI devices we obtained metrics of memory size (from 0.3% to 160.6% RAM, and from 0.9% to 21.3% flash), inference time (from 0.39 to 1463.91 ms), and average consumption (from 0.15 to 5.30 mA). Nine out of ten models were proven viable for deployment. We concluded that the four models based on magnetometer data were significantly better in terms of consumption and inference time. To the best of our knowledge, the use of magnetometer data is a very uncommon approach to failure detection in predictive maintenance applications, and this is probably the first time it has been used for peristaltic pump aging detection, so our results are very promising for future applications. Also, since most trained models use little resources, we have proved that our approach is perfectly compatible with running other communication and control algorithms on the same device, which is ideal for easy integration and scalability in industrial systems. Some limitations for real deployment include facing environmental factors (noise) and long-term monitoring, so we also proposed a protocol that should reduce the impact of those factors by taking measurements in a controlled way.

IEEE Transactions on ReliabilityVol. 74(3)
Universidad de Sevilla (ES), Tokushima University (JP)
Openalex Percentile: Top 19%
Belt Conveyor Systems Engineering
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.