PPY-fMWCNT Nanocomposite-Based Chemicapacitive Biosensor for Ultrasensitive Detection of TBI-Specific GFAP Biomarker in Human Plasma
Traumatic brain injury (TBI) is physical damage to the brain and a significant cause of mortality and morbidity affecting all ages worldwide, remaining as a diagnostic and therapeutic challenge to date. The design and development of rapid, low cost, highly accurate, and long-term stable point-of-care TBI diagnostic test kits is an unmet clinical need. In light of this, here we report a novel multianalyte chemicapacitive immunosensing platform that can detect FDA-approved Glial Fibrillary Acidic Protein (GFAP) biomarkers in real-time human plasma samples using carboxylic functionalized MWCNTs (fMWCNTs) embedded Polypyrrole (PPY) as a bioelectrical transducer. Herein, the low-cost GFAP bioelectrodes were prepared through covalent immobilization of anti-GFAP-antibodies on PPY-fMWCNTs modified array of interdigitated microelectrodes (IDµEs, fabricated on low-cost single-side copper clad PCB substrates). The binding event of GFAP peptides with anti-GFAP-antibodies in real-time human plasma samples was captured in terms of ac capacitance measured through C-F analysis (using an Agilent B1500A parametric analyzer) and quantified in terms of normalized change in capacitance of GFAP bioelectrodes with and without exposure of target GFAP peptides spiked in real-time human plasma samples (10 fg/mL – 1 µg/mL). The proposed PPY-fMWCNTs nanocomposite-based chemicapacitive immunosensing platform effectively detected GFAP target analytes in linear detection range 10 fg/mL – 10 ng/mL with a sensitivity and LoD of 3.9743 ((ΔC/C<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>)/ng·mL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup>)/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and 0.3854 fg/mL, respectively. Further, it also showed superior performance in terms of selectivity, reproducibility, long-term stability (30 weeks) and interference resistance. The proposed ac-capacitive approach is facile, label-free and can be combined with dc-resistive measurements to improve the diversity of decision-making parameters that inherently aid in improving the diagnostic accuracy of TBI test kit.
Authors
- Shiv Govind Singh (ORCID: https://orcid.org/0000-0001-7319-879X)
- Rahul Gangwar (ORCID: https://orcid.org/0000-0003-3391-4362)
- Suryasnata Tripathy (ORCID: https://orcid.org/0000-0002-9159-4224)
- Siva Rama Krishna Vanjari (ORCID: https://orcid.org/0000-0001-6753-2800)
- Patta Supraja (ORCID: https://orcid.org/0000-0002-8962-5263)
Institutions
- SRM University, Andhra Pradesh (IN)
- Indian Institute of Technology Hyderabad (IN)
Publication Details
- Journal
- IEEE Sensors Letters
- Published
- 2024-11-15
- DOI
- https://doi.org/10.1109/lsens.2024.3497003
- Citations
- 2
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.42