Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar

Heart rate variability (HRV), indicating the variation in intervals between consecutive heartbeats, is a crucial physiological indicator of human health. However, detecting HRV using frequency-modulated continuous-wave (FMCW) radar is highly susceptible to interference from respiration, minor body movements, and environmental noise, especially in multitarget scenarios. To address these challenges, we propose the Health-Radar system, which comprises three functional modules. In the target detection module, the system accurately identifies the number and locations of targets. In the phase extraction module, the signal undergoes dc offset calibration to extract the chest displacement signals. In the heartbeat signal extraction module, we introduce Health-VMD, an adaptive parameter variational mode decomposition (VMD) method. This method optimizes the VMD parameters using an improved grasshopper optimization algorithm (GOA) and accurately extracts vital sign signals from chest displacement signals to estimate HRV. In addition, we propose a novel objective function, composed of permutation entropy, mutual information, and energy loss rate (PME), specifically designed for vital sign extraction. Experiments with multiple participants in various scenarios demonstrated that the designed system can accurately identify different targets and detect HRV with high precision. The root-mean-square error (RMSE) of the detected interbeat intervals (IBIs) is 29.72 ms, the RMSE of the standard deviation of NN intervals (SDNN) is 4.1 ms, and the RMSE of the root mean square of successive differences (RMSSD) is 18.61 ms, outperforming existing methods.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-11-15
DOI
https://doi.org/10.1109/jsen.2024.3494755
Citations
8
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar

Yueming Gao, Ye Tao, Zhizhang Chen, Liangqin Chen et al.
8 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
1.48
article

Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar

Yueming Gao, Ye Tao, Zhizhang Chen, Liangqin Chen, Zhimeng Xu
article en
8 citations

Abstract

Heart rate variability (HRV), indicating the variation in intervals between consecutive heartbeats, is a crucial physiological indicator of human health. However, detecting HRV using frequency-modulated continuous-wave (FMCW) radar is highly susceptible to interference from respiration, minor body movements, and environmental noise, especially in multitarget scenarios. To address these challenges, we propose the Health-Radar system, which comprises three functional modules. In the target detection module, the system accurately identifies the number and locations of targets. In the phase extraction module, the signal undergoes dc offset calibration to extract the chest displacement signals. In the heartbeat signal extraction module, we introduce Health-VMD, an adaptive parameter variational mode decomposition (VMD) method. This method optimizes the VMD parameters using an improved grasshopper optimization algorithm (GOA) and accurately extracts vital sign signals from chest displacement signals to estimate HRV. In addition, we propose a novel objective function, composed of permutation entropy, mutual information, and energy loss rate (PME), specifically designed for vital sign extraction. Experiments with multiple participants in various scenarios demonstrated that the designed system can accurately identify different targets and detect HRV with high precision. The root-mean-square error (RMSE) of the detected interbeat intervals (IBIs) is 29.72 ms, the RMSE of the standard deviation of NN intervals (SDNN) is 4.1 ms, and the RMSE of the root mean square of successive differences (RMSSD) is 18.61 ms, outperforming existing methods.

IEEE Sensors JournalVol. 25(1)
Dalhousie University (CA), Fuzhou University (CN)
Science and Technology Projects of Fujian Province, National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 19%
Non-Invasive Vital Sign Monitoring
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.