Feasibility of a heat pump-assisted liquid desiccant system for continuous dehumidification and regeneration in temperate oceanic climatic greenhouses

• Self-circulated liquid desiccant system is developed for greenhouse cultivation applications. • Three different halide desiccants are studied: LiCl/H 2 O, CaCl 2 /H 2 O and HCOOK/H 2 O. • Dynamic moisture content and moisture effectiveness characteristics are studied in detail. • Maximum dehumidification effectiveness is found to be around 76% with LiCl solution. • Min moisture: 7.64 g/kg da via LiCl dehumidification, max regeneration: 23.9 g/kg da with CaCl 2 . Effective thermo-hygrometric control is essential for buildings and greenhouses, particularly in green and low-carbon production. There is growing interest in integrating heat pumps with liquid desiccant systems to enhance energy efficiency and reduce system size in air moisture control. The current study investigates a novel liquid desiccant system combined with a heat pump for continuous, energy-efficient dehumidification and regeneration in horticultural crop cultivation in greenhouses. The uniqueness of the developed system lies in its integration, contrasting with previous liquid desiccant systems designed with separate dehumidifier and regenerator. A semi-theoretical model is developed and validated using in-house experimental datasets to simulate novel liquid desiccant system performance. Results demonstrate that the system effectively maintains air humidity levels, with a maximum enthalpy demand for dehumidification of 99.1 kJ/kg at a solution temperature difference of 40 °C during summer. The minimum achieved moisture content with lithium chloride, calcium chloride, and potassium formate is 7.64 g/kg da , 8.1 g/kg da , and 7.78 g/kg da , respectively, while regeneration produces maximum moisture contents of 23.5 g/kg da , 23.9 g/kg da , and 23.7 g/kg da . The system's maximum effectiveness reaches 76 %, 75 %, and 74 % for lithium chloride, calcium chloride, and potassium formate, respectively. When dehumidification demand exceeds 1,500 h annually, the payback period is five years or less, making the system suitable for new installations and retrofits. A case study considering outdoor conditions in the northeastern United Kingdom presents simulation results for two distinct scenarios, demonstrating the system's potential in real-world applications.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2024-11-15
DOI
https://doi.org/10.1016/j.enconman.2024.119256
Citations
16
Primary Topic
Greenhouse Technology and Climate Control
Type
article
Field-Weighted Citation Impact
9.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of a heat pump-assisted liquid desiccant system for continuous dehumidification and regeneration in temperate oceanic climatic greenhouses

Zhiwei Ma, James Bean, Alessandro Giampieri, Anthony Paul Roskilly et al.
16 citations
Energy Conversion and Management
Greenhouse Technology and Climate Control
9.59
article

Feasibility of a heat pump-assisted liquid desiccant system for continuous dehumidification and regeneration in temperate oceanic climatic greenhouses

Zhiwei Ma, James Bean, Alessandro Giampieri, Anthony Paul Roskilly, Mrinal Bhowmik
article en
16 citations

Abstract

• Self-circulated liquid desiccant system is developed for greenhouse cultivation applications. • Three different halide desiccants are studied: LiCl/H 2 O, CaCl 2 /H 2 O and HCOOK/H 2 O. • Dynamic moisture content and moisture effectiveness characteristics are studied in detail. • Maximum dehumidification effectiveness is found to be around 76% with LiCl solution. • Min moisture: 7.64 g/kg da via LiCl dehumidification, max regeneration: 23.9 g/kg da with CaCl 2 . Effective thermo-hygrometric control is essential for buildings and greenhouses, particularly in green and low-carbon production. There is growing interest in integrating heat pumps with liquid desiccant systems to enhance energy efficiency and reduce system size in air moisture control. The current study investigates a novel liquid desiccant system combined with a heat pump for continuous, energy-efficient dehumidification and regeneration in horticultural crop cultivation in greenhouses. The uniqueness of the developed system lies in its integration, contrasting with previous liquid desiccant systems designed with separate dehumidifier and regenerator. A semi-theoretical model is developed and validated using in-house experimental datasets to simulate novel liquid desiccant system performance. Results demonstrate that the system effectively maintains air humidity levels, with a maximum enthalpy demand for dehumidification of 99.1 kJ/kg at a solution temperature difference of 40 °C during summer. The minimum achieved moisture content with lithium chloride, calcium chloride, and potassium formate is 7.64 g/kg da , 8.1 g/kg da , and 7.78 g/kg da , respectively, while regeneration produces maximum moisture contents of 23.5 g/kg da , 23.9 g/kg da , and 23.7 g/kg da . The system's maximum effectiveness reaches 76 %, 75 %, and 74 % for lithium chloride, calcium chloride, and potassium formate, respectively. When dehumidification demand exceeds 1,500 h annually, the payback period is five years or less, making the system suitable for new installations and retrofits. A case study considering outdoor conditions in the northeastern United Kingdom presents simulation results for two distinct scenarios, demonstrating the system's potential in real-world applications.

Energy Conversion and ManagementVol. 323
Durham University (GB), Crystal Research (United States) (US)
Climate action
Openalex Percentile: Top 2%
Greenhouse Technology and Climate Control
9.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.